KitchenAid 9750520 REV A installation instructions LO n, Panel C

Page 4

Push cable, located on rear of

range, up and into the two hooks on the anti-tip bracket. Check that cable is secure in both hooks by pulling cable towards range. If cable comes out of hooks,

reposition cable to insure that cable fits securely in both anti-tip bracket hooks. Slide range into final position.

/17/. If installing the range in a mobile home, you MUST secure the range to

the floor. Any method of securing the range is adequate as long as it conforms to the standards listed in the Mobile Home Installation Instructions, Panel A.

Place rack in oven. Place level on rack, first side to side; then front to

back. If range is not level, adjust the leveling legs up or down until the range is level.

Note: Oven must be level for satisfactory baking

conditions.

OFF

 

LO n

HI

each surface unit control knob to “HI” position. Check the operation of the

cooktop elements and indicator lights.

120“88:88” should appear in the clock

n

disolav. Press the “Clock Set” button. “TIME, HR AND-MIN will light up in the display. “0:OO”will appear and the “:”will be flashing.

Press the number buttons for the correct time of day. Press “Start/Enter” button to start the clock.

Check the operation of the oven element. Press the “BAKE” button.

“350”” will appear in the temperature display. The ON, Bake Element, Outer Broil Element and Oven Cavity symbols will light up in the display. Press the “Start/Enter” button.

The bottom element should glow red and the indicator light should be on. The upper element should become hot but not glow red. The oven indicator light goes off when the oven is preheated.

Press “Cancel/OFF” button.

122. Check the operation of the broil element. Press the “BROIL” button.

“500”” will appear in the temperature display. The ON, Inner and Outer Broil Elements and Oven Cavity symbols will light up in the display. Press the “Start/Enter” button.

The top element should glow red and the indicator light should be on.

Press the “Cancel/OFF” button.

To get the most efficient use from your new electric range, read your KitchenAid Use and Care Guide. Keep Installation Instructions and Guide close to the electric range for easy reference.

4-wire electrical connection

Use this wiring method for mobile homes and whenever 4.wire installation is required.

U.L. llsted conduit connecxor

If appliance is to be connected directly to fused disconnect or circuit breaker box: Assemble a U.L.-listed conduit connector in

the conduit connector opening provided. Inset-f the power supply cable through the conduit connector, allowing enough slack to easily attach the wiring to the terminal block.

U.L.-&ted strain relief show

I

----‘ClampIng screws

If a U.L.-listed, 40-ampere range power supply cord (pigtail) is used:

Remove the knockout for the 40.ampere power supply cord. Assemble a U.L.-listed strain relief in the hole. Insert the power supply cord through the strain relief, allowing enough slack to easily attach the wiring to the terminal block.

Do not loosen the factory installed nuts already installed on the terminal block.

8.9. IO. 11.15. ‘6.

Remove the grounding-link

screw

from

 

the

range frame. Save the grounding

screw. Bend

up rhe grounding link

so that

it does

not

contact the range.

 

 

ding

Green -

Insulated wire

18.

IW

Numbers

 

 

correspond

 

 

to steps.

l-z-l-

lk.l. -Connect the green grounding wire to the range using the grounding screw

removed in Step B. The green grounding wire must be attached first and must not contact any other terminal.

Sllver-colored terminal block screw

Green - Insulated wlre

- U.L. llsted strain relief shown.

PI. Connect the neutral (white) wire to the center, silver-colored terminal screw on

the terminal block. Connect the other two wires to the outer terminals on the terminal block. Use ring- type terminals only. Connect and securely tighten the brass nuts that are provided on a plastic strip attached to the range. Do Not loosen the factor-y installed nuts already on the terminal.

Be sure that the nuts are installed tight.

(El. Tighten the strain relief clamping screws or the locking ring and clamping screws

of the conduit connector. Replace the terminal block cover.

Continue installation at Step 12, Panel B.

Panel C