JVC DLA-HD550, DLA-HD990, RS-232C, DLA-HD950 manual Acknowledgement Response Return Codes Advanced

Page 9

JVC D-ILA Projector Remote Control Guide

Acknowledgement Response Return Codes - Advanced

For some functions, it is possible to obtain a more detailed response from the projector. This is useful where different actions are required depending on the current projector settings or status. To request the detailed response, taking the above example of the Power Command, we would send to the projector:

3F 89 01 50 57 0A

If the projector receives the enquiry command, as a confirmation that it has received the command, it will first respond with exactly the same information as that returned by the basic Acknowledgement Return Code shown on page 8:

06 89 01 50 57 0A

Next, the projector will send the detailed response. It will send:

40 89 01 50 57 RR 0A – Where RR is the Detailed Response Return Code.

For clarity, the two returned responses are separated here. In practice, they are returned from the projector as one continuous string.

For the power Status Enquiry, the possible values for the Detailed Response Return Code status (RR) are:

30 – Standby

31 – Power On

32 – Cooling

34 – Emergency

So, as a full worked example, if we send to the projector:

3F 89 01 50 57 0A

If the projector were currently cooling down after being switched to Standby, it would return:

06 89 01 50 57 0A 40 89 01 50 57 32 0A

If the projector were on Standby, it would return:

06 89 01 50 57 0A 40 89 01 50 57 30 0A

A list of all of the useful enquiry codes, together with all possible detailed responses is below:

Power Status (to confirm the current Power Status)

Enquiry Command (to projector)

3F 89 01 50 57 0A

 

Response (from projector)

06 89 01 50 57 0A 40 89 01 50 57 RR 0A

 

 

 

 

Response (RR)

Meaning

 

30

Standby

31

Power On

32

Cooling

34

Emergency

Page 9 of 14

Image 9
Contents DLA-HD990 DLA-RS10 / DLA-RS20 DLA-RS15 / DLA-RS25 DLA-RS35 Introduction RS-232C Command TypesPower Direct CommandsAscii Remote Control Emulation Commands Hex CodeCommand Hex Code Ascii Hercules Setup Utility Free from Converting & Testing CodesFunction Acknowledgement Response Acknowledgement Response Return Codes BasicAcknowledgement Response Return Codes Advanced Power Status to confirm the current Power StatusGamma Table to confirm the current Gamma Table Input Status to confirm the current Video InputGamma Value to confirm the current Gamma Value Source Status to confirm the current Video Source StatusDLA-RS15 Model Status to confirm the current Projector ModelDiagram of Data Format ConnectorRS-232C Interface Details Communication ParametersCommand Command FormatError Handling Section Size CommentsInfrared Control