Elmo PSS User Guide | Product Description |
| |
|
|
Term. | Function | Comment | |
Block | connector |
|
|
1 | 12 - 22 (J2) | Power output return (PR) | For DIN mounting, all six pins must be |
|
|
| connected. |
224 - 32 (J1)
For DIN mounting, all five pins must be connected.
314 - 22 (J1)
For DIN mounting, all five pins must be connected.
44 - 12 (J1)
For DIN mounting, all five pins must be connected.
524 - 32 (J2) Positive power output (VP+) For DIN mounting, all five pins must be connected.
6* | 4 (J2) | Inhibit indication output | Whenever power supply is inhibited |
|
|
| (e.g. during thermal/duty cycle), this |
|
|
| open collector output goes into low |
|
|
| state (maximum sink current: 10 mA, |
|
|
| 30 VDC). |
7** | 8 (J2) | Fan supply | 24 VDC/0.5 A output for an external |
|
|
| brushless fan. Common is available in |
|
|
| terminal 1 |
Table
*Inhibit indication return is available in terminal 1.
**Available for 60A types only.
2.2Fault Protection
All PSS products include the following protective functions, which activate the internal inhibit:
Inhibits shunt when heatsink temperature exceeds 90 °C (194 °F).
Duty cycle
Inhibits shunt whenever On and Off time exceeds 5% to 10% (depending on PSS model). This feature protects the shunt regulator when