Fairchild HCPL-3700 manual Recommended Operating Conditions, Symbol Parameter Value Units

Page 2

Absolute Maximum Ratings (No derating required up to 70°C)

Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be operable above the recommended operating conditions and stressing the parts to these levels is not recommended. In addition, extended exposure to stresses above the recommended operating conditions may affect device reliability. The absolute maximum ratings are stress ratings only.

Symbol

 

Parameter

Value

Units

 

 

 

 

 

TSTG

Storage Temperature

 

-55 to +125

°C

TOPR

Operating Temperature

-40 to +85

°C

TSOL

Lead Solder Temperature

260 for 10 sec

°C

EMITTER

 

 

 

 

 

 

 

 

 

IIN

Input Current

Average

50 (Max.)

mA

 

 

Surge, 3ms, 120Hz Pulse Rate

140 (Max.)

 

 

 

 

 

 

 

 

Transient, 10µs, 120Hz Pulse Rate

500 (Max.)

 

 

 

 

 

 

VIN

Input Voltage (Pins 2-3)

-0.5 (Max.)

V

PIN

Input Power Dissipation(1)

230 (Max.)

mW

PT

Total Package Power Dissipation(2)

305 (Max.)

mW

DETECTOR

 

 

 

 

 

 

 

 

IO

Output Current (Average)(3)

30 (Max.)

mA

VCC

Supply Voltage (Pins 8-5)

-0.5 to 20

V

VO

Output Voltage (Pins 6-5)

-0.5 to 20

V

PO

Output Power Dissipation(4)

210 (Max.)

mW

Notes:

1.Derate linearly above 70°C free-air temperature at a rate of 1.8 mW/°C.

2.Derate linearly above 70°C free-air temperature at a rate of 2.5 mW/°C.

3.Derate linearly above 70°C free-air temperature at a rate of 0.6 mA/°C.

4.Derate linearly above 70°C free-air temperature at a rate of 1.9 mW/°C.

Recommended Operating Conditions

The Recommended Operating Conditions table defines the conditions for actual device operation. Recommended operating conditions are specified to ensure optimal performance to the datasheet specifications. Fairchild does not recommend exceeding them or designing to absolute maximum ratings.

Symbol

Parameter

Min.

Max.

Units

 

 

 

 

 

VCC

Supply Voltage

2

18

V

TA

Operating Temperature

0

70

°C

f

Operating Frequency

0

4

kHz

 

 

 

 

 

HCPL-3700 AC/DC to Logic Interface Optocoupler

©2005 Fairchild Semiconductor Corporation

www.fairchildsemi.com

HCPL-3700 Rev. 1.0.1

2

Image 2
Contents Description FeaturesSchematic Package To Logic Interface ApplicationsRecommended Operating Conditions Symbol Parameter Value UnitsSymbol Parameter Min Max Units HCPL-3700 AC/DC to Logic Interface OptocouplerSymbol Parameter Test Conditions Min Typ Max Unit Symbol AC Characteristics Test Conditions Min Typ Max Unit Symbol Characteristics Test Conditions Min Typ Max UnitTypical Performance Curves HCPL-3700 AC/DC to Logic InterfaceAC/DC to Logic Interface Optocoupler HCPL-3700To Logic Through Hole Lead Spacing Package Dimensions3700 AC/DC Surface MountOption Example Part Number Description Ordering InformationMarking Information DefinitionsCarrier Tape Specifications Reflow ProfileTo Logic Interface Optocoupler Trademarks