Conettix C900V2 Installation Guide 4.0 C900V2 Configuration Setup Instructions

7.Type 1 and press [ENTER] to set up Channel 1 configuration.

This information appears.

If the default value displayed in your Telnet window does not match the value listed in any of the steps below, type the correct value and press [ENTER].

8.At the Baud Rate prompt, press [ENTER] to accept the default (9600).

9.At the I/F Mode prompt, press [ENTER] to accept the default (4C).

10.At the Flow prompt, press [ENTER] to accept the default (00).

11.Type a unique Port Number for the LAN to which the C900V2 is connected and press [ENTER].

12.At the ConnectMode prompt, press [ENTER] to accept the default (CC).

13.At the Datagram Type prompt, type 01 and press [ENTER].

14.At the IP addr prompt, type the remote IP address used for the receiver to which the C900V2 reports and press [ENTER].

Enter the remote IP address using 000.000.000.000 format.

15.Type the Port Number for the receiver and press [ENTER].

If you want to enable encryption, continue with the next step. If not, go to step 27.

If you enable encryption on the C900V2, you must enable encryption on the D6680 with the same key.

16.From the Change Setup menu, type 6 and press [ENTER].

This information appears.

17.At the Disable SNMP prompt, press [ENTER] to accept the default (N).

18.At the SNMP Community Name prompt, press [ENTER] to accept the default (public).

19.At the Disable Telnet Setup prompt, press [ENTER] to accept the default (N).

20.At the Disable Port 77FEh prompt, press [ENTER] to accept the default (N).

Disabling both the telnet and port 77FE prevents you from accessing the set-up menu for future changes.

21.At the Disable Web Server prompt, press [ENTER] to accept the default (N).

22.At the Disable ECHO ports prompt, press [ENTER] to accept the default (Y).

23.At the Enable Encryption prompt, type y and press [ENTER].

24.At the Change keys prompt, type y and press [ENTER].

25.Type the key programmed for the receiver and press [ENTER].

The key is 16 bytes (32 characters) long. Enter the key using the 01-02-03-04-05-06-07-08-09- 10-11-12-13-14-15-16 format.

26.At the Enable Enhanced Password prompt, press [ENTER] to accept the default (N).

27.Type 9 and press [ENTER] to save changes and exit the telnet session.

To confirm that the IP address is configured properly, use the ping utility:

Bosch Security Systems, Inc. 8/08 F01U087780-01

17

Image 17
Contents Conettix C900V2 UL Listings and Approvals TrademarksContents Introduction InstallationMounting Optional Mounting PlateAttaching to Enclosure Door Separate Enclosure Mounting Attaching the Module to the Enclosure DoorWiring to a DS7400Xi in the Same Enclosure WiringInput Functions Power Terminal StripTelephone Connections Output FunctionsSetting P3 SetupSetting the DIP Switches Ethernet Connector PinsDIP Switches Dialer Format of Host Alarm Panel Digital Dialer Protocol DIP Switches 1 through 4,Switch State Function DIP Switches 5 throughLEDs System LED LEDDialer LED Functions System LED FunctionsColor State Function Color StateCondition Fallback Mode Occurs Intercept Mode Restored Fallback Mode Dialer InteractionDialer Interaction Forcing C900V2 into Fallback Mode Dynamic Host Configuration Protocol Dhcp C900V2 Configuration Setup InstructionsInitial IP Address Assignment Using ARP.EXE Identifying the MAC Hardware Address Starting Windows 98SE, ME Telnet Select Start Æ Run Using Telnet to Finish the Configuration Select Start Æ Run Starting Windows 2000/XP Telnet Netmask Address Configuration Using TelnetHost Bits Netmask Host Netmask BitsPage Anti-Substitution Protection UL Standard 1610 and ULC S304 Intrusion System Installations Panel Telco Other Connection C900V2 Connection Control Panel ConnectionProtected Premises Control Panel with Digital Dialer Backup Installation at the Protected Premises UL Standard 864 for Fire System InstallationsPanel Telco OUT1-R C900V2 Connection Control Panel Connection Other ConnectionSpecifications SpecificationsCompatible Receiver Formats Radionics SIA Bell Pulse Appendix C900V2 Compatible Data FormatsCompatible Central Station Receiver Formats Bosch Security Systems, Inc. F01U087780-01