AMX NI-4100, NI-2100 manual NI-3100 Specifications, Front Panel LEDs

Page 10

Introduction

NI-3100 Specifications

Dimensions (HWD):

• 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)

 

• 2 rack units high

 

 

Power Requirement:

900 mA @ 12 VDC

 

 

Memory:

• 64 MB SDRAM

 

• 1 MB Non-volatile (NV) SRAM

 

 

Compact Flash:

128 MB or more

 

• AMX may increase Flash size at any time in response to market availability

 

• Upgradeable - see Other AMX Equipment

 

 

Weight:

4.55 lbs (2.06 kg)

 

 

Enclosure:

Metal with black matte finish

 

 

Certifications:

FCC Part 15 Class B, CE, and IEC 60950

 

 

Front Panel LEDs:

 

 

 

• LINK/ACT:

Green LED blinks when the Ethernet cables are connected and

 

terminated correctly. Also blinks when receiving Ethernet data

 

packets.

 

 

• Status:

Green LED blinks to indicate that the system is programmed and communi-

 

cating properly.

 

 

• Output:

Red LED blinks when the Controller transmits data, sets channels On and

 

Off, sends data strings, etc.

 

 

• Input:

Yellow LED blinks when the Controller receives data from button pushes,

 

strings, commands, channel levels, etc.

 

 

RS-232/422/485:

7 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 7 are trans-

 

mitting or receiving RS-232, 422, or 485 data.

 

 

• Relay:

Eight-channel single-pole single-throw relay ports

 

• Each relay is independently controlled.

 

• Supports up to 8 independent external relay devices

 

• Channel range = 1-8

 

• Each relay can switch up to 24 VDC or 28 VAC @ 1 A

 

Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay

 

termination

 

 

• IR/Serial:

8 red LEDs light to indicate the IR/Serial channels 1 - 8 are

 

transmitting control data on Ports 9 - 16. LED indictor for each IR port

 

remains lit for the length of time that IR/Serial data is being generated.

 

 

• I/O:

8 yellow LEDs light when the rear I/O channels 1 - 8 are active. The LED for

 

each I/O port reflects the state of that particular port.

 

 

Rear Panel Components:

 

 

 

RS-232/422/485 (Ports 1 - 7):

7 RS-232/422/485 control ports using DB9 (male) connectors with XON/

 

XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and

 

300-115,200 baud.

 

 

• ICSNet:

2 RJ-45 connectors for ICSNet interface (provided by optional

 

ICSNet daughter card).

 

 

• ICSHub Out:

RJ-45 connector provides data to a Hub connected to the Controller (pro-

 

vided by optional ICSNet daughter card).

 

 

• Relay (Port 8):

8-channel single-pole single throw relay ports with each relay being indepen-

 

dently controlled and supporting up to 8 independent

 

external relay devices.

 

 

• Digital I/O (Port 17):

8-channel binary I/O port for contact closure with each input being capable of

 

voltage sensing. Input format is software selectable with interactive power

 

sensing for IR ports.

 

 

6

NI-2100, NI-3100, NI-4100 Hardware Reference Guide

Image 10
Contents NI-x100 Series AMX Limited Warranty and Disclaimer Table of Contents Table of Contents NetLinx Integrated Master Controller Features Card FG2105-10NI-2100 Specifications FrontFront Panel LEDs Rear Panel ComponentsSettings NI-3100 Specifications NI-3100 NetLinx Integrated Controller front viewNI-3100 Specifications Settings NI-4100 Specifications NI-4100 NetLinx Integrated Controller front viewNI-4100 Specifications Front Panel LEDs/SlotsSettings Related Documents Page Installation and Upgrading Installing NetLinx Control Cards NI-4100 OnlyDevicePortSystem DPS Setting the NetLinx Control Card Addresses NI-4100 OnlyPosition Removing NetLinx Control Cards NI-4100 Only Compact Flash UpgradesOptional Compact Flash Upgrades Product Name DescriptionInstallation of Compact Flash Upgrades Installing Into An Equipment Rack Closing and Securing the Outer HousingInstall screws Bracket Rack Mounting Holes Program Run Disable PRD Mode Setting the Configuration DIP Switch for the Program PortBaud Rate Settings Baud Rate Settings on the Configuration DIP SwitchWorking With the Configuration DIP Switch Setting the CardFrame DIP Switch NI-4100 OnlyProgram Port Connections and Wiring Program Port, Pinouts, and SignalsModes and LED Blink Patterns Modes and Front Panel LED Blink PatternsPort Assignments and Functionality NI-2100 Port AssignmentsWiring Guidelines NI-2100 @ 700 mA Wiring GuidelinesWiring length guidelines Wiring Guidelines NI-3100 & NI-4100 @ 900 mAWiring a Power Connection Preparing Captive WiresUsing the 4-Pin Mini-Phoenix Connector For Data and Power DB9 Device Port Connections and Wiring RS-232 RS-422 RS-485ICSNet RJ-45 Signals ICSNet Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications RJ-45 Pinout Information EIA/TIA 568 BICSHub OUT Pinouts and Signals ICSHub OUT Port Connections and WiringRelay Port Connections and Wiring Pin Signal ColorPort Wiring Specifications NI-4100 and NI-3100 Input/Output I/O Port Connections and WiringPort Wiring Specifications NI-2100 NetLinx Control Card Slot Connector NI-4100 only IR/Serial Port Connections and WiringIR/Serial Connector Wiring Specifications per Port Pin Signals Connections Pairing Color Ethernet/RJ-45 Port Connections and WiringEthernet RJ-45 Pinouts and Signals Ethernet LEDsEthernet Port Descriptions Ethernet Ports Used By the Integrated ControllerPort type Description Standard Port # Page It’s Your World Take Control

NI-2100, NI-3100, NI-4100 specifications

The AMX NI-4100, NI-2100, and NI-3100 are sophisticated, next-generation control systems designed to enhance the automation and management of audiovisual (AV) environments in various professional settings. These devices are built to streamline user interactions and improve overall efficiency in managing complex AV installations.

The AMX NI-4100 stands as one of the most robust solutions in this lineup, featuring a powerful processor that can handle intensive processing tasks seamlessly. With its impressive memory capacity, the NI-4100 supports large-scale installations, making it ideal for corporate environments, educational institutions, and large auditoriums. This device operates on the latest version of the AMX control system software, ensuring compatibility with existing AV equipment. It also incorporates advanced networking capabilities, allowing for integration with multiple devices over an Ethernet network. The NI-4100 is equipped with numerous I/O ports, including multiple serial and IR outputs, offering extensive connectivity options for controlling various devices.

The AMX NI-3100, while slightly less powerful than the NI-4100, offers many essential features for small to medium-sized applications. It is designed with a focus on user experience, boasting an intuitive interface that simplifies operation for users. The NI-3100 supports the powerful AMX programming environment, which enables easy customization and programming of the control system to suit specific needs. Like its counterpart, the NI-3100 offers robust networking options and is capable of handling multiple device integrations, but in a more compact form factor. This makes it an excellent choice for conference rooms, huddle spaces, and education sectors where expertise in AV handling is not always present.

The AMX NI-2100 is the most compact model in the series, tailored for environments where space and budget considerations are paramount. Despite its smaller size, the NI-2100 shares many core functionalities seen in its larger counterparts. It maintains essential control features and reliable performance, making it suitable for smaller installations such as breakout rooms or smaller classrooms. The NI-2100 supports the same programming environment, ensuring it can be integrated into existing AMX solutions without compatibility issues.

All three models leverage AMX's innovative technology, allowing for seamless integration with a diverse range of third-party AV devices, enhancing the capability and scalability of any AV installation. They are also designed with security protocols to protect against unauthorized access, ensuring that the AV environments remain secure. Overall, the AMX NI-4100, NI-3100, and NI-2100 represent a complete suite of control solutions for varying AV needs, proving to be versatile assets in the modern multimedia landscape.