AMX NI-3100, NI-2100 manual NI-4100 Specifications, Front Panel LEDs/Slots

Page 13

Introduction

NI-4100 Specifications

Dimensions (HWD):

• 5.21" x 17.00" x 9.60" (13.23 cm x 43.18 cm x 24.27 cm)

 

• 3 rack units high

 

 

Power Requirement:

• 900 mA @ 12 VDC

Memory:

• 64 MB SDRAM

 

• 1 MB Non-volatile (NV) SRAM

 

 

Compact Flash:

128 MB or more

 

• AMX may increase Flash size at any time in response to market

 

availability

 

• Upgradeable - see Other AMX Equipment

 

 

Weight:

9.15 lbs (4.15 kg)

Enclosure:

Metal with black matte finish

Certifications:

FCC Part 15 Class B, CE, and IEC 60950

Front Panel LEDs/Slots:

 

• LINK/ACT:

Green LED blinks when the Ethernet cables are connected and

 

terminated correctly. Also blinks when receiving Ethernet data

 

packets.

 

 

• Status:

Green LED blinks to indicate that the system is programmed and commu-

 

nicating properly.

 

 

• Output:

Red LED blinks when the Controller transmits data, sets channels On and

 

Off, sends data strings, etc.

 

 

• Input:

Yellow LED blinks when the Controller receives data from button pushes,

 

strings, commands, channel levels, etc.

 

 

RS-232/422/485:

7 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 7 are

 

transmitting or receiving RS-232, 422, or 485 data.

 

 

• Relay:

8 red LEDs light to indicate the relay channels 1 - 8 are active (closed).

 

These LEDs reflect the state of the relay on Port 8.

 

 

• IR/Serial:

8 red LEDs light to indicate the IR/Serial channels 1 - 8 are

 

transmitting control data on Ports 9 - 16. LED indictor for each IR port

 

remains lit for the length of time that IR/Serial data is being generated.

 

 

• I/O:

8 yellow LEDs light when the rear I/O channels 1 - 8 are active. The LED

 

for each I/O port reflects the state of that particular port.

NetLinx Control Card Slots 1 - 4: Accepts up to 4 compatible NetLinx Cards: such as the NXC-COM2, NXC- I/O10, etc.

Rear Panel Components:

RS-232/422/485 (Ports 1 - 7): 7 RS-232/422/485 control ports using DB9 (male) connectors with XON/ XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200 baud.

• ICSNet:

2 RJ-45 connectors for ICSNet interface (provided by optional

 

ICSNet daughter card).

 

 

• ICSHub Out:

RJ-45 connector provides data to a Hub connected to the Controller (pro-

 

vided by optional ICSNet daughter card).

 

 

• Relay (Port 8):

Eight-channel single-pole single throw relay ports

 

• Each relay is independently controlled.

 

• Supports up to 8 independent external relay devices

 

• Channel range = 1-8

 

• Each relay can switch up to 24 VDC or 28 VAC @ 1 A

 

Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay

 

termination

Digital I/O (Port 17):8-channel binary I/O port for contact closure with each input being capable of voltage sensing. Input format is software selectable with interactive power sensing for IR ports.

IR/Serial (Ports 9 - 16): 8 IR/Serial control ports support high-frequency carriers of up to 1.142 MHz with each output being capable of two electrical formats: IR or Serial.

8 IR/Serial data signals can be generated simultaneously.

IR ports support data mode (at limited baud rates and wiring distances).

NI-2100, NI-3100, NI-4100 Hardware Reference Guide

9

 

 

Image 13
Contents NI-x100 Series AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Card FG2105-10 NetLinx Integrated Master Controller FeaturesFront NI-2100 SpecificationsRear Panel Components Front Panel LEDsSettings NI-3100 NetLinx Integrated Controller front view NI-3100 SpecificationsNI-3100 Specifications Settings NI-4100 NetLinx Integrated Controller front view NI-4100 SpecificationsFront Panel LEDs/Slots NI-4100 SpecificationsSettings Related Documents Page Installing NetLinx Control Cards NI-4100 Only Installation and UpgradingDevicePortSystem DPS Setting the NetLinx Control Card Addresses NI-4100 OnlyPosition Optional Compact Flash Upgrades Compact Flash UpgradesRemoving NetLinx Control Cards NI-4100 Only Product Name DescriptionInstallation of Compact Flash Upgrades Closing and Securing the Outer Housing Installing Into An Equipment RackInstall screws Bracket Rack Mounting Holes Baud Rate Settings Setting the Configuration DIP Switch for the Program PortProgram Run Disable PRD Mode Baud Rate Settings on the Configuration DIP SwitchProgram Port Connections and Wiring Setting the CardFrame DIP Switch NI-4100 OnlyWorking With the Configuration DIP Switch Program Port, Pinouts, and SignalsPort Assignments and Functionality Modes and Front Panel LED Blink PatternsModes and LED Blink Patterns NI-2100 Port AssignmentsWiring length guidelines Wiring GuidelinesWiring Guidelines NI-2100 @ 700 mA Wiring Guidelines NI-3100 & NI-4100 @ 900 mAWiring a Power Connection Preparing Captive WiresUsing the 4-Pin Mini-Phoenix Connector For Data and Power RS-232 RS-422 RS-485 DB9 Device Port Connections and WiringRS-232/422/485 Device Port Wiring Specifications ICSNet Port Connections and WiringICSNet RJ-45 Signals RJ-45 Pinout Information EIA/TIA 568 BRelay Port Connections and Wiring ICSHub OUT Port Connections and WiringICSHub OUT Pinouts and Signals Pin Signal ColorPort Wiring Specifications NI-4100 and NI-3100 Input/Output I/O Port Connections and WiringPort Wiring Specifications NI-2100 NetLinx Control Card Slot Connector NI-4100 only IR/Serial Port Connections and WiringIR/Serial Connector Wiring Specifications per Port Ethernet RJ-45 Pinouts and Signals Ethernet/RJ-45 Port Connections and WiringPin Signals Connections Pairing Color Ethernet LEDsEthernet Port Descriptions Ethernet Ports Used By the Integrated ControllerPort type Description Standard Port # Page It’s Your World Take Control

NI-2100, NI-3100, NI-4100 specifications

The AMX NI-4100, NI-2100, and NI-3100 are sophisticated, next-generation control systems designed to enhance the automation and management of audiovisual (AV) environments in various professional settings. These devices are built to streamline user interactions and improve overall efficiency in managing complex AV installations.

The AMX NI-4100 stands as one of the most robust solutions in this lineup, featuring a powerful processor that can handle intensive processing tasks seamlessly. With its impressive memory capacity, the NI-4100 supports large-scale installations, making it ideal for corporate environments, educational institutions, and large auditoriums. This device operates on the latest version of the AMX control system software, ensuring compatibility with existing AV equipment. It also incorporates advanced networking capabilities, allowing for integration with multiple devices over an Ethernet network. The NI-4100 is equipped with numerous I/O ports, including multiple serial and IR outputs, offering extensive connectivity options for controlling various devices.

The AMX NI-3100, while slightly less powerful than the NI-4100, offers many essential features for small to medium-sized applications. It is designed with a focus on user experience, boasting an intuitive interface that simplifies operation for users. The NI-3100 supports the powerful AMX programming environment, which enables easy customization and programming of the control system to suit specific needs. Like its counterpart, the NI-3100 offers robust networking options and is capable of handling multiple device integrations, but in a more compact form factor. This makes it an excellent choice for conference rooms, huddle spaces, and education sectors where expertise in AV handling is not always present.

The AMX NI-2100 is the most compact model in the series, tailored for environments where space and budget considerations are paramount. Despite its smaller size, the NI-2100 shares many core functionalities seen in its larger counterparts. It maintains essential control features and reliable performance, making it suitable for smaller installations such as breakout rooms or smaller classrooms. The NI-2100 supports the same programming environment, ensuring it can be integrated into existing AMX solutions without compatibility issues.

All three models leverage AMX's innovative technology, allowing for seamless integration with a diverse range of third-party AV devices, enhancing the capability and scalability of any AV installation. They are also designed with security protocols to protect against unauthorized access, ensuring that the AV environments remain secure. Overall, the AMX NI-4100, NI-3100, and NI-2100 represent a complete suite of control solutions for varying AV needs, proving to be versatile assets in the modern multimedia landscape.