A X C E S S P R O C E S S O R C A R D S
AXC-EM
Enhanced System Master Card
FG711
Fully compatible with Axcess software, the AXC-EM manages system operation and executes control system programs. This Enhanced Master Card can coordinate the activities of up to 255 different pieces of equipment, such as other control cards, bus controllers and various input devices. These include AMX Tiltscreens, touch panels, softwire panels, wireless receivers and custom panel interfaces.
APPLICATION
•Provides AXCESS Master processing and features to CardFrame
PROCESSOR
•Motorola 16-bit M68340
MEMORY
•Standard – 64KB; Optional – 256KB
INCLUDES
•One status LED for power and AXLink operation
•Master Program Port, male DB-9 connector
•Setup switch for Master Port baud rate, parity, stop bits, and data bits
AXC-S
CardFrame Server Card
FG705
APPLICATION
•Manages communication among control cards in CardFrame
PROCESSOR
•Motorola MC68HC705
INCLUDES
•One status LED for power and AXLink operation
•One front-mounted AXLink jack for local testing of panels and Bus Controllers
•Setup switch to set starting device number to CardFrame
A X C E S S D A T A C O N T R O L C A R D S
AXC-232
RS-232/422/485 Interface Card
FG725
Many audiovisual and computer based devices can be controlled remotely by using RS-232 or RS-422 commands. The AXC-232 RS-232/422/485 Interface Card can generate a virtually unlimited number of product/function commands as they are programmed into the AXC-M Master Card. As needs and technology changes, existing cards can be reprogrammed or new cards added, one for each device.
APPLICATION
•RS-232/422/485 data control transmit and receive
CONTROL PORT
•RS-232, RS-422/485 data port (300-38,400 baud)
INCLUDES
•Two status LED indicators for transmit and receive
•One setup switch for baud rate, parity, stop bits, and data bits
•One micro-jumper for 100 ohm RS-422 termination
•One micro-jumper for RS-422 or RS-485 operation
POWER: 125 mA @12 VDC
CONFIDENTIAL INFORMATION © 2003 AMX Corporation. All rights reserved. AMX and the AMX logo are all trademarks of AMX Corporation. AMX reserves the right to alter specifications without notice at any time. AMX does not assume responsibility for any errors or omissions.
AXC-232++
RS-232/422/485 Interface Card (enhanced functionality)
FG725-10
Many audiovisual and computer-based devices can be remotely controlled using RS-232 or RS-422 commands. The AXC-232++ RS-232/422 Interface Card can generate virtually unlimited numbers of product/function commands as they are programmed into the AXC-EM Master Card. As needs and technology change, existing cards can be reprogrammed or new cards added, one for each device.
APPLICATION
•Advanced RS-232/422/485 data control and receive
CONTROL PORT
•RS-232/422/485 port (300-115,200 baud), XON/XOFF, CTS/RTS
INCLUDES
•Onboard 32-bit processor and 384KB non-volatile memory
•1,000 Byte serial input buffer; 1,000 Byte AXLink buffer
•Two status LED indicators for transmit and receive
•One setup switch for baud rate, parity, stop bits, and data bits
•One micro-jumper for 100 ohm RS-422 termination
•One micro jumper for RS-422 or RS-485 operation
POWER: 160 mA @ 12 VDC
DIMENSIONS (HXD): 2.7" x 12.8" (69.3 mm x 325.6 mm)
WEIGHT: 4.8 oz (136.1 g)
AXC-X10
X-10 Power Line Interface Card
FG747-K
The X-10 system is a unique way to control various devices in the home by sending the commands throughout the house via the built-in AC wiring. X-10 system modules can turn electric lights on and off, start and stop motors and pumps, open and close drapes, water the lawn, heat up the hot tub, and start the coffee maker. The AXC-X10 X-10 Power Line Interface Card, when used with the X-10 Power Line Interface Module, provides direct control of most X- 10 modules with all the programming features of the AMX Axcess system. The AXC-X10 can handle up to 256 devices on each system, using all 16 house and unit codes.
APPLICATION
•Controls up to 256 devices that accept X-10 power line control commands
CONTROL PORT
•X-10 control port
INCLUDES
•Three status LEDs for online, transmit, and receive (future version)
•X-10 Power Line Interface Module model #TW-523 with cab
For more information about AMX products and services visit www.amx.com
11-03