AMX AXP-CPI16 manual Switch Wiring Diagrams, Connecting the AXlink Wiring

Page 9

Switch Wiring Diagrams

FIG. 2 diagrams LED and Switch wiring.

LED Wiring (Typical)

LED 1

1K

 

1

LED 2

1K

10

2

LED 3

1K

 

3

 

Switch Wiring (Typical)

 

SW 1

 

13

12

SW 2

14

SW 3

15

FIG. 2 LED and switch wiring diagrams

Connecting the AXlink Wiring

To install the AXlink data/power bus wiring.

1.Strip 0.25 inch off the wire insulation for all four wires. If the wire is 20 AWG or less, fold the exposed wire over to obtain a positive connection.

2.Insert each wire into the appropriate opening on the connector, as shown in FIG. 3.

PWR

AXlink AXP

AXM

GND

FIG. 3 AXlink wiring diagram

PWR

AXP Device

AXM

GND

3.Tighten the screws to secure the fit.

AXP-CPI16 16-Channel Custom Panel Interface

5

 

 

Image 9
Contents AXP-CPI16 AMX Limited Warranty and Disclaimer Table of Contents Page Product Information SpecificationsProgram is not loaded Mounting Dimensions InstallationConnecting the Two 20-pin Headers Setting the AXlink Device NumberConnecting the AXlink Wiring Switch Wiring DiagramsPage Programming SendCommandsTesting the Unit AXP-CPI16 System Worksheet Channel Page It’s Your World Take Control