Programming
Programming
There are two modes of Channel Assignments: Discrete Output and Default Mode. Both modes are set using the
Status ON Mode Channel Assignment
I/O |
| Corresponding Channel | ||
|
| Assignment |
| |
|
|
| ||
Inputs 1 - 8 | Channels 1 | - 8 (On/Push/Off/Release) | ||
|
|
|
| |
Outputs 1 | - 8 | Channels 9 | - 16 (On/Off only) | |
|
|
| ||
Inputs 9 - 16 | Channels 17 - 24 | (On/Push/Off/Release) | ||
|
|
|
| |
Outputs 9 | - 16 | Channels 25 - 32 | (On/Off only) | |
|
|
|
|
|
Status OFF Mode Channel Assignment
I/O |
| Corresponding Channel | |||
|
| Assignment |
|
| |
|
|
|
| ||
Inputs 1 - 8 | Channels 1 | - 8 | (Push/Release only) | ||
|
|
|
|
| |
Outputs 1 | - 8 | Channels 1 | - 8 | (On/Off only) | |
|
|
|
| ||
Inputs 9 - 16 | Channels 9 | - 16 | (Push/Release only) | ||
|
|
|
|
| |
Outputs 9 | - 16 | Channels 9 | - 16 | (On/Off only) | |
|
|
|
|
|
|
Levels
By default all levels have a data type of byte
The input and output Level values will not be sent until a ’LEVON’ command message is received by the CPI16. A transmission of levels will cease after the receipt of a ’LEVOFF’ command.
The values of Levels 1 and 2 (quadrature inputs) will be sent whenever the input changes.
Levels
Level Function
1Quadrature Input 1
2Quadrature Input 2
3Bargraph 1 (Outputs 1 - 8) - if configured for bargraph mode
4Bargraph 2 (Outputs 9 - 16) - if configured for bargraph mode
5 | |
|
|