Programming

Programming

There are two modes of Channel Assignments: Discrete Output and Default Mode. Both modes are set using the ‘STATUS-ON’ and ‘STATUS-OFF’ commands. Discrete Output mode should be used if channel status feedback for the outputs needs to be separate from the inputs. The tables below provide channel assignment information on both modes. For more information, refer to the Send_Commands section on page 6.

Status ON Mode Channel Assignment

I/O

 

Corresponding Channel

 

 

Assignment

 

 

 

 

Inputs 1 - 8

Channels 1

- 8 (On/Push/Off/Release)

 

 

 

 

Outputs 1

- 8

Channels 9

- 16 (On/Off only)

 

 

 

Inputs 9 - 16

Channels 17 - 24

(On/Push/Off/Release)

 

 

 

 

Outputs 9

- 16

Channels 25 - 32

(On/Off only)

 

 

 

 

 

Status OFF Mode Channel Assignment

I/O

 

Corresponding Channel

 

 

Assignment

 

 

 

 

 

 

Inputs 1 - 8

Channels 1

- 8

(Push/Release only)

 

 

 

 

 

Outputs 1

- 8

Channels 1

- 8

(On/Off only)

 

 

 

 

Inputs 9 - 16

Channels 9

- 16

(Push/Release only)

 

 

 

 

 

Outputs 9

- 16

Channels 9

- 16

(On/Off only)

 

 

 

 

 

 

Levels

By default all levels have a data type of byte (8-bits), which gives a range of 0-255 for the Level Value. The ‘LVL_SZ’ Send_Command sets the size of the value for levels 1 - 4. It is important that the variable in any SEND_LEVEL command and CREATE_LEVEL statement in the NetLinx program match the data type selected by the ‘LVL_SZ’ Send_Command. Incorrect levels may occur if the data types do not match.

The input and output Level values will not be sent until a ’LEVON’ command message is received by the CPI16. A transmission of levels will cease after the receipt of a ’LEVOFF’ command.

The values of Levels 1 and 2 (quadrature inputs) will be sent whenever the input changes.

Levels

Level Function

1Quadrature Input 1

2Quadrature Input 2

3Bargraph 1 (Outputs 1 - 8) - if configured for bargraph mode

4Bargraph 2 (Outputs 9 - 16) - if configured for bargraph mode

NXP-CPI16 NetLinx Custom Panel Interface

5

 

 

Image 9
Contents NXP-CPI16 AMX Limited Warranty and Disclaimer Table of Contents Page NXP-CPI16 Product InformationNXP-CPI16 Specifications SpecificationsQuadrature Connectors Input and Output ConnectorsConnector Pinouts Quadrature Connector PinoutsQuadrature Inputs Status OFF Mode Channel Assignment Status on Mode Channel AssignmentProgramming LevelsSendCommands SendCommandsLvlsz Qdir Input/Output Status Mode NXP-CPI16 NetLinx Custom Panel Interface System Worksheets CH9 Page It’s Your World Take Control