Agilent Technologies 34937A, 34939A manual 34938A 20-Channel High-Current GP Switch Module

Page 15

34938A 20-Channel High-Current GP Switch Module

34938A 20-Channel High-Current GP Switch Module

The 34938A high- current GP switch module provides twenty 5 A Form A (SPST) relays for general purpose switching needs. You can set the power- failure state for these 5 A relays (see “Hardware Power- Fail Jumper” on page 2).

N O T E

A temperature sensor on these modules triggers system interrupts

when high-carry current-induced heat on the modules reaches a

 

 

threshold of 70 oC. See description of the “HOT” annunciator on

 

page 2.

 

 

34938A Simplified Schematic

NO

COM

NO

COM

Channel 001 (5A Form A)

Channel 020 (5A Form A)

Agilent 34937A-34939A General Purpose Switch Modules User’s Guide

9

Image 15
Contents Agilent 34937A-34939A General Purpose Switch Modules 34980-90037 Agilent Technologies, IncAdditional Safety Notices Frame or chassis terminalUnited States 800 Europe 31 20 547 Japan Declaration of Conformity DoC for the 34980A mainframe Contents Page General Purpose Switch Modules Operating Considerations Temperature SensorSwitching Reactive Loads Hardware Power-Fail JumperOpen Power Down State34937A, 34938A and 34939A Scpi Programming Examples Opening and Closing ChannelsReading Jumper State and System Identity Command resets a module in slot 4 to its power- on state Reading Cycle Count and Resetting Modules to Power-On State34937A Simplified Schematic 34937A 32-Channel GP Switch Module34937A D-Sub Connectors 34937T Terminal Block Wire Size AWG Typical AWG Max34938A Simplified Schematic 34938A 20-Channel High-Current GP Switch Module34938A D-Sub Connectors 34938T Terminal Block 34939A Simplified Schematic 34939A 64-Channel High-Density Form-A GP Switch Module34939A D-Sub Connectors 34 no 41 no 48 no 55 no 62 no Male ConnectorPin D-Sub 33 no 40 no 47 no 54 no 61 no34939T Terminal Block 34939A 64-Channel High-Density Form-A GP Switch Module Jumper Temperature sensorIndex