Agilent Technologies 34937A, 34939A manual 34939T Terminal Block, Wire Size AWG Typical AWG Max

Page 21

34939A 64-Channel High-Density Form-A GP Switch Module

34939T Terminal Block

This terminal block with screw- type connections is labeled with the model number and the abbreviated module name. In addition, space is available on the label for you to write the slot number.

The 34980A Product Reference CD (shipped with the instrument) contains a 34939T Wiring Log for you to document your wiring configuration for this module. You can open the wiring log file in Microsoft® Excel® or Adobe® Acrobat® format.

Wire Size:

20 AWG Typical

18 AWG Max

1

2

3

4

5

6

C NO C NO C NO C NO C NO C NO

C NO C NO C NO C NO C NO C NO

7

8

9

10

11

12

13

14

15

16

17

18

C NO C NO C NO C NO C NO C NO

C NO C NO C NO C NO C NO C NO

19

20

21

22

23

24

25

26

27

28

29

30

 

C NO C NO C NO C NO C NO C NO

C NO C NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

32

 

 

 

 

 

 

 

 

 

 

 

 

33

34

35

36

37

38

C NO C NO C NO C NO C NO C NO

C NO C NO C NO C NO C NO C NO

39

40

41

42

43

44

45

46

47

48

49

50

C NO C NO C NO C NO C NO C NO

C NO C NO C NO C NO C NO C NO

51

52

53

54

55

56

57

58

59

60

61

62

 

C NO C NO C NO C NO C NO C NO

C NO C NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

64

 

 

 

 

 

 

 

 

 

 

 

 

 

Agilent 34937A-34939A General Purpose Switch Modules User’s Guide

15

Image 21
Contents Agilent 34937A-34939A General Purpose Switch Modules 34980-90037 Agilent Technologies, IncAdditional Safety Notices Frame or chassis terminalUnited States 800 Europe 31 20 547 Japan Declaration of Conformity DoC for the 34980A mainframe Contents Page General Purpose Switch Modules Switching Reactive Loads Temperature SensorHardware Power-Fail Jumper Operating ConsiderationsOpen Power Down State34937A, 34938A and 34939A Scpi Programming Examples Opening and Closing ChannelsReading Jumper State and System Identity Command resets a module in slot 4 to its power- on state Reading Cycle Count and Resetting Modules to Power-On State34937A Simplified Schematic 34937A 32-Channel GP Switch Module34937A D-Sub Connectors 34937T Terminal Block Wire Size AWG Typical AWG Max34938A Simplified Schematic 34938A 20-Channel High-Current GP Switch Module34938A D-Sub Connectors 34938T Terminal Block 34939A Simplified Schematic 34939A 64-Channel High-Density Form-A GP Switch Module34939A D-Sub Connectors Pin D-Sub Male Connector33 no 40 no 47 no 54 no 61 no 34 no 41 no 48 no 55 no 62 no34939T Terminal Block 34939A 64-Channel High-Density Form-A GP Switch Module Jumper Temperature sensorIndex