AMX AVS-SL-PR-0401-0601 manual Attenuation Changes Level on selected Input only, Mute OFF

Page 14

SET Commands

Attenuation (Changes Level on selected Input only)

The Volume level increases 0.5db each time the following command is sent:

Byte 1 Byte 2 Byte 3

(Header) (Address) (Increase)

E8

00 to FF 0D

The Volume level decreases 0.5db each time the following command is sent:

Byte 1 Byte 2 Byte 3

(Header) (Address) (Decrease)

E8

00 to FF 0E

Absolute Attenuation Level

An attenuation value can be set directly using the following command:

Byte 1

Byte 2

Byte 3

Byte 4

(Header)

(Address)

 

(Volume Value)

E8

00 to FF

0F

00 to 1F

with 00 as (0dB) Mute ON

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

E8

00 to FF

0B

Mute OFF

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

E8

00 to FF

0C

Front Panel Disable

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

E8

00 to FF

40

Front Panel Enable

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

E8

00 to FF

41

Memory Reset (sets 2011 to Default Factory Settings)

Byte 1 Byte 2 Byte 3

38 62 DC

Change Address (Sets 2011 to New Address)

Byte 1 Byte 2 Byte 3 Byte 4

(Address number)

38 62 D9 00 - FF

8

AVS-SL-PR-0401-0601

Image 14
Contents AVS-SL-PR-0401-0601 AMX Limited Warranty and Disclaimer Safety Instructions Safety Instructions AVS-SL-PR-0401-0601 Table of Contents Device Manager Product Specifications OverviewSync Output Connections Typical Installation For Use With a ProjectorPower Up Video ConnectionsConnections Operation Front PanelRS232 Control Input mode onlyPower On/Off mode Display ConnectionsSET Commands Input SwitchingMemory Reset sets 2011 to Default Factory Settings Front Panel DisableFront Panel Enable Attenuation Changes Level on selected Input onlyRequest Address GET CommandsSwitch and Volume Status Feedback Request Attenuation LevelsIdentity Command Operation Device ManagerConnection Manufacturers data sheet will be required Device Manager AVS-SL-PR-0401-0601 It’s Your World Take Control