AMX AVS-SL-PR-0401-0601 manual GET Commands, Switch and Volume Status Feedback, Request Address

Page 15

GET Commands

GET Commands

Switch and Volume Status Feedback

Transmit

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

EF

00 to FF

80

Receive

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

(Header)

(Address)

 

 

 

C8

00 to FF

PC or Video Input

Audio input

Input volume level

 

 

0= Blank

 

 

 

 

1 to 4 = PC I/P

 

 

 

 

5 to 0A= Vid I/P

 

 

The same string will be transmitted each time an input is selected.

Request Address

Transmit

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

38

62

DA

Receive

Byte 1

Byte 2

(Header)

(Address)

C8

00 to FF

Request Attenuation Levels

Transmit

Byte 1

Byte 2

Byte 3

(Header)

(Address)

 

EF

00 - FF

40

Receive

Byte 1

Byte 2

Byte 3

4

5

6

7

8

9

10

11

12

(Header)

(Address)

 

 

 

 

 

 

 

 

 

 

C8

00 - FF

40

X

X

X

X

X

X

X

X

X

Where x is a value between 00 and 1F.

AVS-SL-PR-0401-0601

9

 

 

Image 15
Contents AVS-SL-PR-0401-0601 AMX Limited Warranty and Disclaimer Safety Instructions Safety Instructions AVS-SL-PR-0401-0601 Table of Contents Device Manager Overview Product SpecificationsSync Output Video Connections Typical Installation For Use With a ProjectorPower Up ConnectionsConnections Front Panel OperationDisplay Connections Input mode onlyPower On/Off mode RS232 ControlInput Switching SET CommandsAttenuation Changes Level on selected Input only Front Panel DisableFront Panel Enable Memory Reset sets 2011 to Default Factory SettingsRequest Attenuation Levels GET CommandsSwitch and Volume Status Feedback Request AddressIdentity Command Device Manager ConnectionOperation Manufacturers data sheet will be required Device Manager AVS-SL-PR-0401-0601 It’s Your World Take Control