Overview
The NXF CardFrame (FG2001) accommodates a NetLinx Master (or Hub) card, up to twelve NetLinx Control cards, and provides a back plane to distribute power and data to/from the cards (FIG. 1).
FIG. 1 NXF CardFrame - front panel (with faceplate)
The NXF CardFrame provides terminals on the rear panel for connection to the control cards, and to a system power supply. A DIP switch on the rear panel sets the CardFrame's base device number. For detailed product information on the NXF CardFrame, and the NetLinx Control Cards, refer to the NetLinx CardFrame, Control Cards, and NetModules Instruction Manual
Front/Rear Panel Components
FIG. 2 shows the front and rear panel components of the NXF CardFrame:
Front | Control Card connectors |
| |||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Master/Hub Card slot |
|
|
|
|
|
|
|
|
|
|
|
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Installation Guide
NXF NetLinx® CardFrame
Compatible NetLinx Master Cards
For use as a master controller, the NXF CardFrame accepts the following NetLinx Master Card:
NetLinx Master Card
Compatible NetLinx Hub Cards
For use as a hub device, the NXF CardFrame accepts the following NetLinx Hub Cards:
NetLinx Hub Cards
ICSNet Hub Card (FG2060) | |
|
|
ICSHub Server Card (FG2061) | |
|
|
ICSHub Expander Card (FG2062) | |
|
|
Control Card Connectors
1.12 card slots for the NXC Control Cards that control devices connected to the CardFrame. To install NXC Control Cards in the NXF CardFrame:
2.Remove the magnetic front faceplate/viewing window from the CardFrame.
3.Align the edge of the Control Card with a slot in the CardFrame. Slide the card into the CardFrame and press until you feel the Card seat in the back- plane connector.
4.Put the magnetic faceplate back on the CardFrame. Secure with mounting screws (if necessary).
Compatible NXC Control Cards:
The NXF CardFrame accepts the following NetLinx Control Cards:
| 12 | 11 | 10 | 9 |
| 8 | 7 | 6 | 5 |
| 4 | 3 | 2 | 1 |
1 |
|
| 1 |
| 1 |
| 1 |
|
| 1 |
|
| 1 |
|
2 | 2 |
| 2 | 2 | 2 | 2 | 2 |
| 2 | 2 | 2 |
| 2 | 2 |
3 | 3 |
| 3 | 3 | 3 | 3 | 3 |
| 3 | 3 | 3 |
| 3 | 3 |
4 | 4 |
| 4 | 4 | 4 | 4 | 4 |
| 4 | 4 | 4 |
| 4 | 4 |
5 | 5 |
| 5 | 5 | 5 | 5 | 5 |
| 5 | 5 | 5 |
| 5 | 5 |
6 | 6 |
| 6 | 6 | 6 | 6 | 6 |
| 6 | 6 | 6 |
| 6 | 6 |
7 | 7 |
| 7 | 7 | 7 | 7 | 7 |
| 7 | 7 | 7 |
| 7 | 7 |
8 | 8 |
| 8 | 8 | 8 | 8 | 8 |
| 8 | 8 | 8 |
| 8 | 8 |
9 | 9 |
| 9 | 9 | 9 | 9 | 9 |
| 9 | 9 | 9 |
| 9 | 9 |
10 | 10 |
| 10 | 10 | 10 | 10 | 10 |
| 10 | 10 | 10 |
| 10 | 10 |
11 | 11 |
| 11 | 11 | 11 | 11 | 11 |
| 11 | 11 | 11 |
| 11 | 11 |
12 | 12 |
| 12 | 12 | 12 | 12 | 12 |
| 12 | 12 | 12 |
| 12 | 12 |
13 | 13 |
| 13 | 13 | 13 | 13 | 13 |
| 13 | 13 | 13 |
| 13 | 13 |
14 | 14 |
| 14 | 14 | 14 | 14 | 14 |
| 14 | 14 | 14 |
| 14 | 14 |
15 | 15 |
| 15 | 15 | 15 | 15 | 15 |
| 15 | 15 | 15 |
| 15 | 15 |
16 | 16 |
| 16 | 16 | 16 | 16 | 16 |
| 16 | 16 | 16 |
| 16 | 16 |
17 | 17 |
| 17 | 17 | 17 | 17 | 17 |
| 17 | 17 | 17 |
| 17 | 17 |
18 | 18 |
| 18 | 18 | 18 | 18 | 18 |
| 18 | 18 | 18 |
| 18 | 18 |
19 | 19 |
| 19 | 19 | 19 | 19 | 19 |
| 19 | 19 | 19 |
| 19 | 19 |
20 |
|
| 20 |
| 20 |
| 20 |
|
| 20 |
|
| 20 |
|
| 12 | 11 | 10 | 9 |
| 8 | 7 | 6 | 5 |
| 4 | 3 | 2 | 1 |
Control Card slots
PWR (power) connector
CardFrame Number (device ID) DIP switch
FIG. 2 NXF CardFrame - Front/Rear Panel Components
12VDC |
| NXF |
CARDFRAME NUMBER | CARDFRAME | |
| ON |
|
CARDFRAME |
|
|
PWR |
|
|
Master/Hub
Card slot
Rear
NetLinx Control Cards
Dual COM Port Control Card (FG2022) | |
|
|
Input/Output Control Card (FG2021) | |
|
|
|
|
Relay Control Card (FG2020) | |
|
|
Analog Voltage Control Card (FG2025) | |
|
|
Volume Control Card (FG2024) | |
|
|
Specifications
Dimensions | 3.5" x 17.0" x 9.6" (8.90 cm x 43.20 cm x 22.50 cm) |
(HWD): |
|
|
|
Weight: | 9.1 lbs. (4.1 kg) |
|
|
Power | +12 VDC |
Requirement: |
|
|
|
Master/Hub Card Slot
The Master/Hub Card slot houses a NetLinx Master or Hub Card. The card mounts in a horizontal position, through the master card slot on the rear panel of the NXF enclosure. To install a Master or Hub Card in an NXF:
1. Discharge the static electricity from your body by touching a grounded |
object. |
+12 VDC PWR Connector:
On the rear panel. the
CardFrame Number DIP Switch:
The
2. | Disconnect the power, and unplug all connectors from the NXF. |
3. | Remove the two screws that hold the front plate on the Master Card, and |
| remove the front plate. |
4. | Align the edges of the card with the guide slots inside the Master Card slot |
| on the NXF. |
5. | Slide the card about halfway into the slot. |
6. | Inside the Master Card slot on NXF, locate the |
| connector. |
7. | Plug the connector from the NXF into the |
| Card. This connector is keyed to ensure correct orientation. |
1
12VDC
CARDFRAME
PWR
12VDC
PWR
|
|
|
|
| CARDFRAME NUMBER |
|
|
|
|
|
| ON |
|
|
|
| ETHERNET |
|
| |
|
|
| 10/100 |
|
|
|
|
|
| SPEED | FD |
|
|
GND | AXM AXP | PWR | RTS CTS TX | RX | GND |
|
| AXlink |
| PROGRAM | ICSNet | ICSHub |
NXF
NXF
CARDFRAMECardFrame
Number
DIP switch
IN
OUT
8. | Once the control cable is connected, gently slide the card all the way in |
| until you can screw the card in place. |
9. |
1
FIG. 3 CardFrame Number DIP switch