DESIGNER SOLUTIONS

2.[CLR]

This command resets the UT250-101to the last saved configuration.

Command Format: [CLR] Example:

Clear the UT250-101by sending [CLR]. Any commands that were sent to the UT250-101using the [...S] option will be recalled using this command.

3.[VER]

This command displays the model number, firmware version, and unit ID.

Command Format: [VER] Example:

Send the command [VER], and the UT250-101will return feedback similar to the following:

[UT250-101 690-0268-001 U0]

UT250-101 = the model number

690-0268-001 = the firmware version

U0

= the unit ID

4.[ONmX]

This command turns on one or more outputs. Command Format: [ONmX]

m = Output No. (m = 1 or 2)

X = Channel No. (X = A, B, or blank for both) Example:

Turn on Output 1A by sending [ON1A] to the UT250-101. Outputs 1B, 2A, and 2B are unaffected.

Turn on Outputs 2A and 2B by sending [ON2] to the UT250-101. Outputs 1A and 1B are unaffected.

5.[ON]

This command turns on all outputs. Command Format: [ON] Example:

Send [ON] to the UT250-101and all 4 outputs (1A, 1B, 2A, and 2B) will be enabled.

6.[OFFmX]

This command turns off one or more outputs. Command Format: [OFFmX]

m = Output No. (m = 1 or 2)

X = Channel No. (X = A, B, or blank for both) Example:

Turn off Output 1A by sending [OFF1A]. Outputs 1B, 2A, and 2B are unaffected.

Turn off Outputs 2A and 2B by sending [OFF2]. Outputs 1A and 1B are unaffected.

7.[OFF]

This command turns off all outputs. Command Format: [OFF] Example:

Send [OFF] to the UT250-101and all 4 outputs (1A, 1B, 2A, and 2B) will be disabled.

8.[InOmX]

This command connects one input to one output.

Command Format: [InOmX]

n = Input No. (m = # from 1 to 8) m = Output No. (m = 1 or 2)

X = Channel No. (X = A, B, or blank for both) Example:

Connect Input 7 to Outputs 1A and 1B and then Input 6 to Output 2A by sending the commands [I7O1] and [I6O2A]. The first command connects Input 7 to both channels of Output 1. The second command connects Input 6 to Output 2 Channel A only.

400-0503-001

15

Image 16
Contents UT250-101 Table of Contents Precautions / Safety Warnings CleaningGeneral HandlingUT250-101 About Your UT250-101Technical Specifications Specifications are subject to changeMechanical Product Description Application Diagrams Diagram 1 Typical SetupDiagram 2 Internal View Diagram 3 Dimensions Diagram 4 Cable Support Diagram 5 Installation TabletopDiagram 6 Output Select Wiring Installing Your UT250-101 AUTO-SWITCH ModeOperation Manual Control Output Select ControlsDescription of Commands RS-232 Control1 RS-232 Interface StatusCLR VERONmX OFFmXInO 10. …P11. SW AutoHelp 17. ?STA1 STA020. ...S AFBSIDn RSITroubleshooting Guide No Response No Twisted Pair OutputAltinex Policies Limited WARRANTY/RETURN PoliciesContact Information ALTINEX, Inc