[ON…..F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero.

Example:

[ON1C2U3F]: if path is not set

[ON1C2U3PF]: if path is set

5. [OFF]

This command disables one or more outputs of a single card or a group of cards.

[OFFmCnUiS]: for a single card

This command disables output “m” without affecting any other outputs.

m = output number (m = 1 to 8)

n = card ID No. (n = slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

I = Unit ID number (i = 0 to 9)

S = saves command to memory

[OFFCnUi]: Turns OFF all outputs of the card

Example:

1) If card 5 of unit 3 has output 1, 2 and 3 ON:

a)[OFF1C5U3]: Turns OFF output 1 while output 2 and 3 remain ON.

b)[OFF23C5]: Turns OFF output 2 and 3.

2)If card 5 of unit 3 has output 1, 2, 3, 4, 5, 6,

7 and 8 ON:

a)[OFFC5U3]: Turns OFF all outputs, which is equivalent to [OFF12345678C5U3].

[OFFmGkUiS]: for a group of cards

This command disables output "m" for each card in group "k" of unit "i".

Command Format: [OFFmCnUiP]

m = card output (m = # from 1-8)

k = group number (k = # from 1-9) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

i = unit number (i = # from 0-9)

S = saves command to memory

Example:

1.[OFF1G5U1]: Turns OFF output 1 for each card in group5 of unit 1.

2.[OFFG5U1]: Turns OFF all outputs for each card in group5 of unit 1.

[OFF…..P]: sets path

This command will set the path for the output, but it is not active until the switch command is executed ([SW]). Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be loaded.

Command Format: [OFFmCnUiP]

m = output number (m =1 to 8)

n = card ID No. (n = a slot # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

P = path

Example:

If 2 cards are at slot 6 and 7 of unit 3:

To enable output 1 and 2 of card 6 and output 3 and 4 of card 7 simultaneously, use the following commands:

OFF12C6U3P]

[OFF34C7U3P]

[SW]

If "F" is included use the [OFFmCnUiPF] command or the [OFFmCnUiFP] command.

[OFF…..F]: feedback

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero.

11

11

Image 11
Contents MT105-110/MT105-111 Precautions / Safety Warnings General Precautions / Safety WarningsInstallation CleaningMechanical MT105-110/111Description of MT105-110/111 Application Diagram Block Diagrams Internal View of MT105-110/111 Operation Installing Your MT105-110/111Description of Commands Error Codes ON…..P sets path ONmCnUiS for a single cardONmGkUiS for a group of cards OFFmGkUiS for a group of cards ON…..F feedbackOFF OFFmCnUiS for a single cardCLRGkUi for a group of cards SW SwitchCLR CLRCnUi for a single cardNo Display Troubleshooting GuideSummary of Commands Altinex Policy