10. [RD]
This command displays the members in each group.
Command Format: [RDGkUi]
k = group number (k = # from
i = unit number (i = # from
member = C1 - C19 (card 1 to 19) (1 to 8 for
Example:
To read member data for group 5 of unit 1, send the [RDG5U1] command. The system will return feedback as C1C2C3 G5U1
11. [HELP]
This command displays all available commands for
7.3.SUMMARY OF COMMANDS.
1)[VER]: Receives software version
2)[C]: Receives status of the card
3)[IO]: Connects the input to the output
4)[ON]: Turns on one or more outputs for a single card or a group of cards
5)[OFF]: Turns off one or more outputs for a single card or a group of cards
6)[SW]: Switch (outputs the preloaded buffer)
7)[WR]: Groups multiple cards
8)[CLR]: Clears members of a single group or all groups
9)[G]: Requests group data
10)[RD]: Displays the members in each group.
11)[HELP]: Displays all commands
TROUBLESHOOTING GUIDE | 8 |
We have carefully tested and have found no problems in the supplied
NO DISPLAY
Cause 1: The source has a problem.
Solution: | Check the source and make sure, that |
| there is a signal present and all |
| source connections are correct. If the |
| source is working and there is still no |
| display, see Cause 2. |
Cause 2: | The card input is not selected. |
Solution: | Select the card input. See |
| accessible commands in section 7.If |
| no display is present see Cause 3. |
Cause 3: Cable connections to the destination are incorrect.
Solution 1: Make sure that cables are connected properly. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4.
Cause 4: The display has a problem.
Solution 1: Make sure that the display is powered. If there is still no display, call ALTINEX at (714)
13