Altinex 400-0226-003, MT105-111, MT105-110 Troubleshooting Guide, Summary of Commands, No Display

Page 13

MULTI-TASKER

10. [RD]

This command displays the members in each group.

Command Format: [RDGkUi]

k = group number (k = # from 1-9)

i = unit number (i = # from 0-9)

member = C1 - C19 (card 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106)

Example:

To read member data for group 5 of unit 1, send the [RDG5U1] command. The system will return feedback as C1C2C3 G5U1

11. [HELP]

This command displays all available commands for RS-232 control.

7.3.SUMMARY OF COMMANDS.

1)[VER]: Receives software version

2)[C]: Receives status of the card

3)[IO]: Connects the input to the output

4)[ON]: Turns on one or more outputs for a single card or a group of cards

5)[OFF]: Turns off one or more outputs for a single card or a group of cards

6)[SW]: Switch (outputs the preloaded buffer)

7)[WR]: Groups multiple cards

8)[CLR]: Clears members of a single group or all groups

9)[G]: Requests group data

10)[RD]: Displays the members in each group.

11)[HELP]: Displays all commands

TROUBLESHOOTING GUIDE

8

We have carefully tested and have found no problems in the supplied MT105-110/(111); however, we would like to offer suggestions for the following:

NO DISPLAY

Cause 1: The source has a problem.

Solution:

Check the source and make sure, that

 

there is a signal present and all

 

source connections are correct. If the

 

source is working and there is still no

 

display, see Cause 2.

Cause 2:

The card input is not selected.

Solution:

Select the card input. See RS-232

 

accessible commands in section 7.If

 

no display is present see Cause 3.

Cause 3: Cable connections to the destination are incorrect.

Solution 1: Make sure that cables are connected properly. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 4.

Cause 4: The display has a problem.

Solution 1: Make sure that the display is powered. If there is still no display, call ALTINEX at (714) 990-2300.

13

13

Image 13
Contents MT105-110/MT105-111 Precautions / Safety Warnings Installation Precautions / Safety WarningsCleaning GeneralMechanical MT105-110/111Description of MT105-110/111 Application Diagram Block Diagrams Internal View of MT105-110/111 Description of Commands Installing Your MT105-110/111Operation Error Codes ONmGkUiS for a group of cards ONmCnUiS for a single cardON…..P sets path OFF ON…..F feedbackOFFmCnUiS for a single card OFFmGkUiS for a group of cardsCLR SW SwitchCLRCnUi for a single card CLRGkUi for a group of cardsSummary of Commands Troubleshooting GuideNo Display Altinex Policy