8 |
|
| |
| Table 3: PSU LEDs found on all | ||
|
|
|
|
| PSU 1 | Green | PSU 1 is installed and supplying power to the |
|
|
| switch, and the voltage output is within |
|
|
| specification. |
|
|
|
|
|
| Red | PSU 1 is installed in the switch, a fan has failed, |
|
|
| or the PSU has exceeded its recommend |
|
|
| temperature threshold of 75º C (167º F). |
|
|
| A FOM is installed in the switch and a fan has |
|
|
| failed. |
|
|
| The bay is empty (no PSU or FOM installed). |
|
|
|
|
|
| Not lit | A FOM is installed and the fan is good. |
|
|
|
|
| PSU 2 | Green | PSU 2 is installed and supplying power to the |
|
|
| switch, and the voltage output is within |
|
|
| specification. |
|
|
|
|
|
| Red | PSU 2 is installed in the switch, a fan has failed, |
|
|
| or the PSU has exceeded its recommend |
|
|
| temperature threshold of 75º C (167º F). |
|
|
| A FOM is installed in the switch and a fan has |
|
|
| failed. |
|
|
| The bay is empty (no PSU or FOM installed). |
|
|
|
|
|
| Not lit | A FOM is installed and the fan is good. |
|
|
|
|
If the PSU does not function as expected, follow these steps:
1.Check all cable connections are correct and secure.
2.For DC models, check that the standby switch has been pressed and is in the ON position.
For AC models, check the PSU is receiving the correct AC voltage.
3.If the LEDs indicate a PSU fault, replace the PSU or have it serviced by authorised service personnel.
More troubleshooting information can be found in the