APC SU042-1 3000 VA, SU043 1400 VA, SU041 1400 VA user manual Electrical Safety, Handling Safety

Page 7

Safety

This section contains important instructions that should be followed during installation and maintenance of the Redundant Switch. It is intended for customers who setup, install, relocate, or maintain APC equipment.

Electrical Safety

Do not work alone under hazardous conditions.

High short circuit current through conductive materials could cause severe burns.

Check that the power cord(s), plug(s), and sockets are in good condition.

To reduce the risk of electric shock when grounding cannot be verified, disconnect the equipment from the AC power outlet before installing or connecting to other equipment. Reconnect the power cord only after all connections are made.

Do not handle any kind of metallic connector before the power has been removed.

Use one hand, whenever possible, to connect or disconnect signal cables to avoid a possible shock from touching two surfaces with different electrical grounds.

Connect the equipment to a three wire AC outlet (two poles plus ground). The receptacle must be connected to appropriate branch circuit/mains protection (fuse or circuit breaker). Connection to any other type of receptacle may result in a shock hazard.

CAUTION! Deenergizing Safety

To deenergize: press and hold both UPS Off buttons for more than one second to switch the equipment off. Next disconnect the equipment from the AC power outlet.

Pluggable equipment includes a protective earth conductor which carries the leakage current from the load devices (computer equipment). Total leakage current must not exceed 3.5 mA.

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly effect its safety or effectiveness is not recommended.

Handling Safety

⇒ <18 kg (<40 lb.)

32-55 kg (70-120 lb.)

18-32 kg (40-70 lb.)

⇒ >55 kg (>120 lb.)

Be careful. Do not lift heavy loads without assistance.

Equipment with casters is built to move on a smooth surface without any obstacles.

Do not use a ramp inclined at more than 10°.

This equipment is intended for installation in a temperature-controlled (0°- 50°C, +32° - +122°F) indoor area, free of conductive contaminants.

1

990-0253A, Revision 2 6/99

Image 7
Contents Redundant Switch User’s Manual Page English Page Table of Contents Page Electrical Safety SafetyHandling Safety Initial Startup InstallationMount the Ears Install the Rails Connect Equipment Mount the Redundant Switch in the RackPowerChute plus Configuration Procedure Supported ConfigurationsStorage Operating Instructions Loss of Redundancy Problems Troubleshooting Redundant SwitchTroubleshooting the High Availability System Communications ProblemsSpecifications Limited Warranty ServiceAPC Contact Information Rail Hardware Installation Tips for Rack Mount Units

SU042-1 3000 VA, SU42-2 3000 VA, SU041 1400 VA, SU043 1400 VA specifications

The APC SU042-1, SU043, SU041, and SU42-2 are reliable uninterruptible power supply (UPS) systems designed to provide consistent power protection for essential electronic equipment. This range of UPS models is ideal for homes, small offices, and critical servers, ensuring peace of mind through a reliable power backup solution.

The APC SU042-1 is a high-capacity 3000 VA model that combines robust performance with smart technologies. It is equipped with a pure sine wave output, ensuring that sensitive electronics, such as servers and networking equipment, receive clean and stable power. With a compact design, this UPS easily fits into various environments while providing extended runtime options through additional battery packs. The LCD display offers real-time information on battery status, load, and input/output voltage, allowing for quick monitoring and management.

In the mid-range category, the APC SU043 and SU041 models stand out with their 1400 VA capacity. These units are perfect for desktop setups and small servers, offering essential features to protect equipment from power disturbances. Both models feature automatic voltage regulation (AVR), which stabilizes incoming voltage and minimizes the risk of damage from power surges. They also come with multiple output sockets, accommodating a variety of devices while ensuring maximum efficiency.

The SU42-2, another 3000 VA model, provides a higher capacity for businesses looking to safeguard critical infrastructure. Similar to the SU042-1, this unit boasts pure sine wave output and advanced LCD displays for monitoring. Additionally, the SU42-2 features customizable settings that allow users to tailor performance based on specific power needs, such as setting alarms and adjusting sensitivity to voltage fluctuations.

All four models utilize advanced battery management systems to enhance battery life and performance. User-friendly, they come with USB and serial connectivity options, allowing seamless integration with network monitoring software, enabling administrators to manage and monitor power status remotely. In conclusion, the APC SU042-1, SU043, SU041, and SU42-2 UPS models represent a versatile range of solutions designed to protect vital equipment against power disturbances, making them an essential investment for anyone reliant on a steady power supply.