Firmware Upgrade Utility

Introduction

The purpose of the Windows-based firmware upgrade utility is to provide an automated process for upgrading the KVM Rack LCD and compatible adapter cable firmware. The program comes as part of a firmware upgrade package that is specific for each device.

Check www.apc.com regularly to find the latest information and firmware upgrade packages.

Downloading the Firmware Upgrade Package

To download the firmware upgrade package:

1.From a computer that is not part of your KVM installation, go to www.apc.com and enter the model name of your KVM Rack LCD for a list of available firmware upgrade packages.

2.Choose the firmware upgrade package that you wish to install (usually the most recent) and download it.

Preparation

1.Use the Firmware Upgrade Cable (provided) to connect a COM port on your computer to the Firmware Upgrade Port of the KVM Rack LCD.

Note: Cascaded stations will automatically receive the upgrade via the in-series connection cables.

2.From the KVM Rack LCD console, login to the OSD as the administrator (see “OSD Login” on page 11) and select the F4 ADM function.

3.Scroll down to FIRMWARE UPGRADE. Press the Enter key, then press the Y key to invoke the Firmware Upgrade mode (see “FIRMWARE UPGRADE” on page 16).

Note: During the upgrade, the port LEDs will flash on and off.

Start the Upgrade

1.Run the downloaded firmware upgrade file by double-clicking the file icon or opening a command line and entering the full path to the file.

2.Click Next to continue. The Firmware Upgrade Utility main screen appears. The devices capable of being upgraded are listed in the Device List panel.

3.If the Check Firmware Version box (from the Firmware Upgrade Utility main screen) is checked, the utility compares the device’s firmware version with the upgrade files. If the device’s version is newer, the utility lets you decide whether to continue. It the box is not checked, the utility performs the upgrade directly. Click Next to perform the upgrade.

Upgrade Succeeded

After the upgrade has completed, an UPGRADE SUCCEEDED screen appears to inform you that the procedure was successful. Click Finish to close the firmware upgrade utility.

Rack LCD Console KVM Switch User’s Manual

23

Image 27
Contents User’s Manual 동봉된 CD 안에 한국어 매뉴얼이 있습니다 Contents Troubleshooting Specifications Overview Symbols used in this manualCross-reference symbol used in this manual General InformationSafety Components Caps Lock LED FW UpgradeLCD Scroll Lock LEDCompatible Cables Rear ViewBrackets InstallationSingle KVM Rack LCD Installation KVM cable installationsPower On the KVM Rack LCD Server connections Multiple KVM Switches Installed in SeriesInstallation Power On the KVM Rack LCD and KVM switchesBasic Functions OperationPort Selection Monitor settingsSetting Explanation Hot PluggingOn Screen Display OSD Operation OSD Navigation OSD Main ScreenOSD Main Screen Headings Heading DescriptionSetting Description To change a settingSetting Function Scan Duration SCAN-SKIP ModeCommand Mode ModeRestore SET User LoginSET Accessible TimeoutSetting F6 BRC Num Lock + Invoke Hotkey ModeKeyboard Port Operation Hotkey Port ControlSelecting the Active Port Auto Scan ModeQuick Hotkey Control Skip ModeKeyboard/Mouse Reset Hotkey Beeper ControlRestore Default Values OSD Hotkey ControlPort OS Control Hotkey Summary Table Invoke Hotkey Mode Enter Hotkey Mode DescriptionFirmware Upgrade Utility Firmware Upgrade Recovery Upgrade FailedTroubleshooting PS/2, USB SpecificationsConnection Tables OSD Factory Default Settings Sphd ConnectorsDedicated Hotkeys Non-transferable warranty Exclusions WarrantyTwo-Year Factory Warranty Terms of warrantyWarranty claims Canada-ICES Radio Frequency Interference990-3770-001 10/2009 APC Worldwide Customer Support