Linksys SLM224G4S manual Stack Master Failure and Replacement

Page 60

Appendix B

About Switch Stacking

If the incoming unit did not have an assigned Unit ID (that is, it was in factory default mode), it will be assigned the lowest available Unit ID by the Master. It is strongly recommended that automatic assigned unit ID mode be used since it provides better resiliency to the stack.

If the incoming unit already has an assigned Unit ID, and that Unit ID is unused in the current stack, the incoming unit will keep its assigned Unit ID and the Master will apply to it any configuration relevant to that Unit ID.

If the incoming unit already has an assigned Unit ID, and that Unit ID conflicts with a unit ID in the current stack, the Master will reallocate a new Unit ID to the incoming unit, giving it the lowest available Unit ID (assuming, of course, that the incoming unit does not have a manually assigned Unit ID, which the Master cannot change).

If the incoming unit cannot be assigned an available Unit ID for any reason (in the case of unit replacement that can only happen if the incoming unit has a manually assigned Unit ID), then it will be effectively shut down—that is, it will not be joined to the stack.

3.The stack Master will now carry out Unit and port configuration for the incoming unit.

Any configuration information the Master has that is relevant to the number assigned to the incoming unit will be applied. In particular, if the incoming unit was assigned the same Unit ID of the unit it replaces, then it will receive the same configuration as the failed unit, to the extent possible.

If the incoming unit is identical in makeup to the replaced unit, the entire configuration of the replaced unit will be applied to the incoming one and the stack will go back to the state it was in before unit failure. However, sometimes the incoming unit is not identical to the unit that failed in these cases. The stack Master will apply the configuration in the following manner:

If a 24-port unit replaces a failed 48-port unit, then the ports of the incoming unit will be configured according to the way the first 24 ports of the failed unit were configured.

(Note that the configuration of all 48 ports of the failed unit is remembered, even though only the first 24 are currently applied. If, in the future, a 48 port unit is inserted and assigned the same Unit ID, it will be configured as the original failed 48- port unit was configured).

If a 48-port unit replaces a 24-port unit, then the first 24 ports of the incoming unit will be configured according to the way the ports of the failed unit were configured, and the rest of the ports of the incoming unit will be configured at default settings.

If the units (the failed one and its replacement) had/have uplink ports, then the first uplink of the incoming unit will be configured as was the first uplink of the failed unit, and so on.

Stack Master Failure and Replacement

In this example, the master unit fails in a running stack. When notified of the failure, a system administrator removes the failed unit and replaces it with another one.

When the unit fails, the stack Backup Master detects (via the ongoing monitoring Master Discovery process) that the master unit no longer responds and takes over as the stack master. The backup master directs all other stack members to route unit-to-unit traffic around the failed unit using the ring topology of the stacking connections. At the same time the stack Backup Master notifies the system administrator (using SYSLOG messages and SNMP traps) of the failure.

When the failed unit is disconnected from the stack, all traffic will already be routed around it, and as long as all other stacking connections are left intact, the stack should continue to run.

When a new unit is inserted in the stack and powered up, the following will happen:

1.The incoming unit will perform Master discovery, and perhaps participate in a Master Election, as described above.

If the incoming unit has a Unit ID of 1 or 2 (that is, the unit is a master-enabled unit), then Master Election will be initiated. However, since the running stack Backup Master has a longer run time, assuming that it has been running for more then 10 minutes, it will remain elected as the stack Master and the incoming unit will not become a new stack Master. This may result in an incoming unit using Unit ID=1, and serving as the stack backup master, while the already running unit with Unit ID=2 remains the active stack master.

2.The stack Master at this stage will carry out a Unit ID allocation and conflict resolution process.

If the incoming unit did not have an assigned Unit ID (that is, it was in factory default mode), it will be assigned the lowest available Unit ID by the Master. It is strongly recommended that automatic assigned unit ID mode be used since it provides better resiliency to the stack.

24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs

54

Image 60
Contents Port or 48-Port 10/100 + About This Guide About This GuideIcon Descriptions Online ResourcesTable of Contents Snmp Appendix B About Switch Stacking Appendix C GlossaryGigabit Ethernet Fiber Optic Cabling Appendix D Specifications Appendix G Contact InformationChapter IntroductionChapter Product Overview Product OverviewFront Panel Back PanelSLM248G4S Chapter Installation InstallationPre-Installation Considerations Placement OptionsHardware Installation Desktop PlacementRack-Mount Placement Uplinking the Switch Configuring Stacking ModeReplacing a Stacked Switch Connect port G1 on Unit 2 to port G2 on UnitConnect port G1 on Unit 3 to port G2 on Unit Chapter Configuration Using Console Interface Using the HyperTerminal ApplicationUsing telnet Login screen appears. Proceed to the Login section belowHow to Use the Console Interface LoginSwitch Main Menu System Configuration MenuManagement Settings User & Password SettingsSystem Information Security Settings IP ConfigurationNetwork Configuration File ManagementRestore System Default Settings Reboot SystemStack Configuration Port Configuration System ModePort Status HelpChapter Configuration Using Web-based Utility SetupSetup Summary Device InformationSetup Zoom Setup Network SettingsDefault Gateway The IP address default 0.0.0.0 DNS Server The IP address of your ISP’s server thatSetup Time IdentificationLocal Time Daylight SavingSetup Stack Management Port Management Port SettingsPort Management Sntp ServersPort Configuration LAG Configuration Port Management Link AggregationLacp screen contains fields for configuring Lacp LAGs Port Management LacpGlobal Parameter Port PriorityVlan Management Port Settings Vlan ManagementVlan Management Create Vlan Lacp Port TableVlan Management Port to Vlan Vlan Management Vlan to PortJoin Vlan to Port Statistics Statistics Rmon StatisticsStatistics Rmon History Rmon HistoryLog Table Rmon History TableStatistics Rmon Alarms Add AlarmStatistics Port Utilization Statistics Rmon EventsStatistics Interface Statistics Security 802.1x Settings SecurityInterface Ethernet-likeSetting Timer Security Port SecuritySecurity Management Access List Web IP FilteringSecurity Storm Control Security RadiusBroadcast Only Counts only Broadcast traffic QoS CoS Settings CoS SettingsCoS Default CoS Settings screen is used to enable or disable CoSQoS Queue Settings QoS Dscp SettingsQoS Bandwidth QoS Basic Mode Spanning TreeSpanning Tree STP Status Spanning Tree STP Port Settings Global SettingBridge Settings Spanning Tree Global STPVlan Igmp Settings MulticastMulticast Igmp Snooping Igmp GlobalMulticast Bridge Multicast Multicast Bridge Multicast Forward AllSnmp Global Parameters Snmp ViewsSnmp Group Profile Snmp Group MembershipUser Name Provides a user-defined local user list Snmp Communities Snmp Notification Filter Snmp Notification RecipientBase Table Advanced TableAdmin Admin User AuthenticationUser Authentication Local User EditAdmin Static Address Admin Dynamic AddressSecure The entry is defined for locked ports Clear Table If selected, this clears the MAC Address tableAdmin Port Mirroring Admin Cable TestQuery Admin Save Configuration Admin Firmware Upgrade Admin RebootAdmin Factory Default Admin Logging Admin Server LogsAdmin Memory Logs Admin Flash Logs LogoutAppendix a Appendix a About Gigabit Ethernet Fiber Optic CablingGigabit Ethernet Fiber Optic CablingAppendix B About Switch Stacking About Switch StackingAppendix B Stack Building Quick StartAdvanced Stacking Stack ResiliencyUnit IDs Unit ID AllocationStack Units Startup Process Master DiscoveryMaster Election Unit and Port Configuration User ControlsStacking Examples Replacing a Failed Stack Member in a Running StackStack Master Failure and Replacement Subgroup Contains Both Master Unit and Backup Master Unit Splitting a StackMerging Two Stacks Both Stacks Kept Running During InsertionStacking Cable Failure Inserting Too Many UnitsAppendix C Appendix C GlossaryGlossary Glossary Packet a unit of data sent over a network Mail protocol on the InternetAppendix C Appendix D Specifications SpecificationsAppendix D Dimensions HOL Blocking Head of line blocking preventionSupports up to 9K byte frames 802.3 10BASE-T EthernetWarranty Information Limited WarrantyObtaining Warranty Service Appendix EWarranty Information Technical SupportAppendix F Regulatory InformationRegulatory Information Appendix F Norsk Norwegian Miljøinformasjon for kunder i EU Appendix F Appendix G Contact Information

SLM224G4S specifications

The Linksys SLM224G4S is a sophisticated Layer 2 managed switch designed for businesses and institutions that demand high performance, reliability, and advanced networking features. This model stands out due to its blend of robustness and manageability, making it ideal for expanding networks.

One of the primary features of the SLM224G4S is its 24 Gigabit Ethernet ports, allowing for high-speed data transfers essential for bandwidth-intensive applications. Supporting auto-negotiation, these ports can detect the capabilities of connected devices and configure themselves accordingly, ensuring optimal performance without manual intervention. With four additional shared Gigabit SFP (Small Form-factor Pluggable) ports, this switch provides flexibility in network design and enhances scalability.

The SLM224G4S supports VLAN (Virtual Local Area Network) capabilities, which can segment network traffic to improve security and performance. This is particularly useful in environments where different departments or teams require distinct network segments for operational efficiency. By implementing VLANs, organizations can enhance their network management while isolating sensitive information from potential threats.

Quality of Service (QoS) is another critical technology integrated into the SLM224G4S. It prioritizes network traffic, ensuring that critical applications receive the bandwidth they need for optimal performance. This is particularly important for VoIP and video conferencing applications, where latency and jitter can significantly impact user experience.

The switch also features advanced Layer 2 management functionalities, including SNMP (Simple Network Management Protocol), allowing IT administrators to monitor network performance and quickly troubleshoot issues. The embedded web-based management interface makes configuration straightforward, enabling quick adjustments to settings without deep networking knowledge.

Security is a paramount consideration in today’s networking landscape. The SLM224G4S provides robust security features, including port security that limits the number of MAC addresses allowed on a port, reducing the risk of unauthorized access. Moreover, it supports802.1X port-based authentication, ensuring that only authenticated devices can connect to the network.

In summary, the Linksys SLM224G4S managed switch boasts features such as 24 Gigabit Ethernet ports, VLAN support, QoS, SNMP management, and advanced security protocols. These characteristics make it an excellent choice for businesses looking to enhance their network's performance, safety, and reliability, paving the way for seamless connectivity in today’s digital age.