Advantech ADAM-4561 Network Connection, Serial Connection, Wiring for RS-232 Connection

Page 17

2.1.2 Network Connection

When using the ADAM-4561, you will simply plug one end of USB cable (included in package) into ADAM-4561, and the other end into the USB hub or your host PC.

2.1.3 Serial Connection

The model of the ADAM-4561 that you purchased has 10 pin connec- tor for connecting serial ports on the bottom of module. Only one set of twisted-pair cables is required to transmit both Data and RTS signals for RS-485 interface.

Note:

In USB v1.1 standard, If you have used the

 

COM3, COM4….. COMn of host PC. When

 

you plug ADAM-4561 in the host PC, the COM

 

port will be COMn+1.

Wiring for RS-232 Connection

Figure 2.2: Wiring of RS-232 Connection

7

Chapter2

Image 17
Contents Port Isolated USB to RS-232/422/485 Converter ADAM-4561Copyright Acknowledgements Product Warranty 2 years FCC Class a Declaration of ConformityTechnical Support and Assistance FCC Class BSafety Instructions 20 C -4 F or Above 60 C 140 F. this could DAM Viii Contents Page Overview Introduction Features Package Checklist SpecificationsTransmission speed 75 bps to 115.2 Kbps Data bit 5, 6, 7 Stop bit 1, 1.5Installation & Setup Network Architecture Hardware InstallationSerial Connection Wiring for RS-232 ConnectionNetwork Connection Wiring of RS-422 Connection Wiring of RS-485 ConnectionJumper Settings Driver and Utility Installation Software Installation