Adaptec MAN-FC2002-001 manual Figure D-2 Installing the BBU

Page 108

108

Figure D-2 Installing the BBU

BBU Connector

Feed cable through

hole provided and attach

to the connector

Tabs

Tabs

BBU

4Feed the BBU cable through the hole provided and connect it to the BBU connector (see Figure D-2).

5Press the BBU into position and secure it by ensuring the four tabs “click” into place.

6Replace the ACM in the enclosure and tighten the ACM screws to complete the installation.

Image 108
Contents 2Gb SANbloc Series Installation Guide Page Warranty DisclaimerWarranty Warranty R O L O G I C . T H E S E S TA N D a R D E X P R E S S Table of Contents Jbod Configurations Installing and Removing Components Page Appendix D Upgrading a 2Gb SANbloc Jbod Array to a Page Audience Conventions Used In This User GuideGetting Support FCC StatementVcci European Community StatementSafety Statements Following safety statements must be read beforeSafety Statements Safety Statements Features IntroductionIntroduction Power Supplies Disk Drive CarrierFan Speed vs. Temperature Change Cooling SystemExpansion Module Copper/Copper Expansion Module- Optical/Optical 2Gb SANbloc Series Tower Model 2Gb SANbloc Series Rack Model Features Installation and Setup Safety Statements Safety Statements Unpacking and Initial Setup Installing the System in an Equipment RackAmbient Temperature Air Flow Mechanical LoadingSetting Fibre Channel Loop Speed 2Gb or 1Gb Electrical Considerations2Gb Operation 1Gb Operation Location of Jumpers on LS ModuleSetting Up Split Loop Operation Split Fibre Channel Loop Operation Quad LoopRemoving Split Loop Operation Configuration Rules Supported Host Bus AdaptersSupported Cables Copper CablesOptical Cables Jbod Configurations Setting the Enclosure IDLocation of Enclosure ID Switch Disk Drive Identifier Table Configurations Jbod Configurations Dual FC Loop ConfigurationConnecting dual FC Loop configuration to a host Daisy chaining dual FC Loop enclosures Quad Loop Configuration Cabling the Quad Loop ConfigurationConnecting a Power Source Connecting an ACPower Source Disk Drive Spin Up Sequence ModuloRAID Configurations 2Gb SANbloc Series RAID Controller IntroductionRAID Controller Circuit Boards RAID Controller Circuit Boards Controller Circuit BoardCircuit Board Ethernet Circuit Board RAID Controller Location RAID Controller locationRAID Controller Status LEDs Controller Status LEDsRAID Controller Configurations Enclosure ID Switch Configurations Connecting a Single RAID Controller to a Host Single RAID Controller ConfigurationDaisy Chaining a Single Controller Enclosure Daisy Chaining Single Controller Enclosure Connecting Dual RAID Controllers to a Host Sys- tem Dual RAID Controller ConfigurationDaisy Chaining a Dual Controller Enclosure Daisy Chaining a Dual Controller Enclosure Connecting a Power Source Disk Drive Spin Up Sequence Disk Drive Spin Up Sequence System Monitoring OverviewLS Module LS Module Features 2Gb SANblocEnclosure LEDs Location of 2Gb SANbloc Enclosure LEDs Enclosure LED Descriptions Disk Drive LEDs Disk Drive LED DescriptionsDisk Drive Carrier LEDs Power Supply LEDs Power Supply LEDsAdvanced Cooling Module ACM LEDs Advanced Cooling Module LEDsRAID Controller LEDs RAID controller LEDsRAID Controller LEDs Installing and Removing Compo- nents Location of the Components Installing and Removing a Disk Drive Carrier Installing a DiskDrive Carrier Removing a DiskDisk Drive Carrier Installing and Removing an LS Module Installing an LSModule Removing an LSLS Module Installing and Removing a Power Supply Installing a PowerRemoving a Power SupplyInstalling and Removing an Advanced Cooling Module Installing an Advanced Cooling Module Removing anInstalling and Removing an I/O Module/RAID Controller Installing an I/O Module/RAID Controller Removing an I/OInstalling and Removing an I/O Module/RAID Controller Appendix a Safety Statement Translations Page Page Page Page Page Page Page Page Page Appendix B Technical Specifications Host InterfaceDisk Drive Interface SystemPhysical Dimensions MonitoringFailure Notification Deskside EnclosurePower Supply TemperatureAC Power Supply Input Disk DrivesAltitude Operational ShockOperational Vibration Regulatory Agency Compliance 100 Appendix C Configuration Loop Diagrams Loop Diagram for a Dual Enclosure System Single Loop Loop Diagram for a Single Enclosure System Dual Loop Loop Diagram for a Dual Enclosure System Dual Loop Equipment and parts necessary for upgrade Upgrading from Jbod to RAIDDriver Installing the Battery Backup UnitFigure D-2 Installing the BBU 109 110

MAN-FC2002-001 specifications

The Adaptec MAN-FC2002-001 is a high-performance storage controller designed to address the needs of enterprise-level data management. This Fibre Channel host bus adapter (HBA) is engineered to facilitate fast and reliable data transfer between servers and storage devices, thereby enhancing overall storage performance. One of its standout features is the support for 2 Gbps Fibre Channel technology, which enables rapid communication in environments where speed is critical.

This controller is equipped with dual-channel architecture that provides advanced connectivity options. This design not only improves bandwidth utilization but also allows for simultaneous access to multiple storage devices, enhancing system efficiency. With its robust architecture, the MAN-FC2002-001 supports both point-to-point and switched fabric connectivity, giving users flexibility in their configurations based on their unique storage environment.

One of the key technologies incorporated in the Adaptec MAN-FC2002-001 is its advanced error checking and correction capabilities. These features help protect data integrity during transmission, minimizing data loss risks. Additionally, the HBA supports an array of operating systems, including various UNIX distributions and Windows servers, making it a versatile choice for diverse IT infrastructures.

Performance-wise, the controller is optimized for high I/O operations, making it suitable for demanding applications such as databases, virtualization, and large file transfers. With support for advanced queuing techniques, it can efficiently manage a high volume of data requests, thus reducing latency and enhancing response times.

In terms of compatibility, the Adaptec MAN-FC2002-001 easily integrates with external storage arrays, providing users with options to scale their storage solutions as needed. The card is designed for both backward compatibility with older Fibre Channel infrastructures and forward compatibility with the latest technologies, thereby extending the investment value for enterprises.

To complement its technical capabilities, the MAN-FC2002-001 features a comprehensive set of management tools, allowing system administrators to monitor performance metrics, manage firmware updates, and configure settings easily. Its reliable design and robust performance characteristics make the Adaptec MAN-FC2002-001 an ideal choice for organizations looking to enhance their storage network infrastructure while maintaining high availability and reliability. Overall, the Adaptec MAN-FC2002-001 represents a powerful solution for modern data storage challenges.