Adaptec MAN-FC2002-001 manual Location of 2Gb SANbloc Enclosure LEDs

Page 67

67

Figure 5-1 Location of 2Gb SANbloc Enclosure LEDs

SAN bloc

2

Series

0

18F

18F

18F

18F

18F

18F

18F

18F

18F

18F

18F

18F

1

2

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

18F

18F

0

1

2

3

4

5

Gb

LED 0 LED 1 LED 2 LED 3 LED 4 LED 5

0 1

2

3

45

Table 5-1 shows the meaning of each of the LEDs, and how to interpret them.

LS Module

Image 67
Contents 2Gb SANbloc Series Installation Guide Page Disclaimer WarrantyWarranty Warranty R O L O G I C . T H E S E S TA N D a R D E X P R E S S Table of Contents Jbod Configurations Installing and Removing Components Page Appendix D Upgrading a 2Gb SANbloc Jbod Array to a Page Conventions Used In This User Guide AudienceFCC Statement Getting SupportEuropean Community Statement VcciFollowing safety statements must be read before Safety StatementsSafety Statements Safety Statements Introduction FeaturesIntroduction Disk Drive Carrier Power SuppliesCooling System Fan Speed vs. Temperature ChangeExpansion Module Copper/Copper Expansion Module- Optical/Optical 2Gb SANbloc Series Tower Model 2Gb SANbloc Series Rack Model Features Installation and Setup Safety Statements Safety Statements Installing the System in an Equipment Rack Unpacking and Initial SetupAmbient Temperature Mechanical Loading Air FlowElectrical Considerations Setting Fibre Channel Loop Speed 2Gb or 1Gb2Gb Operation Location of Jumpers on LS Module 1Gb OperationSplit Fibre Channel Loop Operation Quad Loop Setting Up Split Loop OperationRemoving Split Loop Operation Supported Host Bus Adapters Configuration RulesCopper Cables Supported CablesOptical Cables Setting the Enclosure ID Jbod ConfigurationsLocation of Enclosure ID Switch Disk Drive Identifier Table Configurations Dual FC Loop Configuration Jbod ConfigurationsConnecting dual FC Loop configuration to a host Daisy chaining dual FC Loop enclosures Cabling the Quad Loop Configuration Quad Loop ConfigurationConnecting an AC Connecting a Power SourcePower Source Modulo Disk Drive Spin Up Sequence2Gb SANbloc Series RAID Controller Introduction RAID ConfigurationsRAID Controller Circuit Boards Controller Circuit Board RAID Controller Circuit BoardsCircuit Board Ethernet Circuit Board RAID Controller location RAID Controller LocationController Status LEDs RAID Controller Status LEDsRAID Controller Configurations Enclosure ID Switch Configurations Single RAID Controller Configuration Connecting a Single RAID Controller to a HostDaisy Chaining a Single Controller Enclosure Daisy Chaining Single Controller Enclosure Dual RAID Controller Configuration Connecting Dual RAID Controllers to a Host Sys- temDaisy Chaining a Dual Controller Enclosure Daisy Chaining a Dual Controller Enclosure Connecting a Power Source Disk Drive Spin Up Sequence Disk Drive Spin Up Sequence Overview System MonitoringLS Module 2Gb SANbloc LS Module FeaturesEnclosure LEDs Location of 2Gb SANbloc Enclosure LEDs Enclosure LED Descriptions Disk Drive LED Descriptions Disk Drive LEDsDisk Drive Carrier LEDs Power Supply LEDs Power Supply LEDsAdvanced Cooling Module LEDs Advanced Cooling Module ACM LEDsRAID controller LEDs RAID Controller LEDsRAID Controller LEDs Installing and Removing Compo- nents Location of the Components Removing a Disk Installing and Removing a Disk Drive CarrierInstalling a Disk Drive CarrierDisk Drive Carrier Removing an LS Installing and Removing an LS ModuleInstalling an LS ModuleLS Module Supply Installing and Removing a Power SupplyInstalling a Power Removing a PowerInstalling an Advanced Cooling Module Removing an Installing and Removing an Advanced Cooling ModuleInstalling an I/O Module/RAID Controller Removing an I/O Installing and Removing an I/O Module/RAID ControllerInstalling and Removing an I/O Module/RAID Controller Appendix a Safety Statement Translations Page Page Page Page Page Page Page Page Page System Appendix B Technical SpecificationsHost Interface Disk Drive InterfaceDeskside Enclosure Physical DimensionsMonitoring Failure NotificationDisk Drives Power SupplyTemperature AC Power Supply InputOperational Shock AltitudeOperational Vibration Regulatory Agency Compliance 100 Appendix C Configuration Loop Diagrams Loop Diagram for a Dual Enclosure System Single Loop Loop Diagram for a Single Enclosure System Dual Loop Loop Diagram for a Dual Enclosure System Dual Loop Upgrading from Jbod to RAID Equipment and parts necessary for upgradeDriver Backup Unit Installing the BatteryFigure D-2 Installing the BBU 109 110

MAN-FC2002-001 specifications

The Adaptec MAN-FC2002-001 is a high-performance storage controller designed to address the needs of enterprise-level data management. This Fibre Channel host bus adapter (HBA) is engineered to facilitate fast and reliable data transfer between servers and storage devices, thereby enhancing overall storage performance. One of its standout features is the support for 2 Gbps Fibre Channel technology, which enables rapid communication in environments where speed is critical.

This controller is equipped with dual-channel architecture that provides advanced connectivity options. This design not only improves bandwidth utilization but also allows for simultaneous access to multiple storage devices, enhancing system efficiency. With its robust architecture, the MAN-FC2002-001 supports both point-to-point and switched fabric connectivity, giving users flexibility in their configurations based on their unique storage environment.

One of the key technologies incorporated in the Adaptec MAN-FC2002-001 is its advanced error checking and correction capabilities. These features help protect data integrity during transmission, minimizing data loss risks. Additionally, the HBA supports an array of operating systems, including various UNIX distributions and Windows servers, making it a versatile choice for diverse IT infrastructures.

Performance-wise, the controller is optimized for high I/O operations, making it suitable for demanding applications such as databases, virtualization, and large file transfers. With support for advanced queuing techniques, it can efficiently manage a high volume of data requests, thus reducing latency and enhancing response times.

In terms of compatibility, the Adaptec MAN-FC2002-001 easily integrates with external storage arrays, providing users with options to scale their storage solutions as needed. The card is designed for both backward compatibility with older Fibre Channel infrastructures and forward compatibility with the latest technologies, thereby extending the investment value for enterprises.

To complement its technical capabilities, the MAN-FC2002-001 features a comprehensive set of management tools, allowing system administrators to monitor performance metrics, manage firmware updates, and configure settings easily. Its reliable design and robust performance characteristics make the Adaptec MAN-FC2002-001 an ideal choice for organizations looking to enhance their storage network infrastructure while maintaining high availability and reliability. Overall, the Adaptec MAN-FC2002-001 represents a powerful solution for modern data storage challenges.