The | The following sections describe how to get your Switch 3300 XM |
Sequence |
|
Connecting a You can connect a SuperStack Advanced Redundant Power System (part Redundant Power number 3C16071B) to the Switch. This unit, which is also known as an
System ARPS, is designed to maintain the power to your Switch if a power supply failure occurs.
For normal redundancy, the unit requires one Type 2A Power Module. For full redundancy, the unit requires two Type 2A Power Modules combined using a Type 2
Check with your supplier that you have the correct Power Modules and cables for your ARPS unit.
CAUTION: The Switch can only use a SuperStack Advanced Redundant
Power System output.
Switch 3300 XM
CAUTION: The Switch has no ON/OFF switch; the only method of connecting or disconnecting main power is by connecting or disconnecting the power cord.
1Plug the power cord into the power socket at the rear of the Switch.
2Plug the other end of the power cord into your power outlet
The Switch
Checking for Correct During the Power On Self Test, all ports on the Switch are disabled and Operation the LEDs light in the following sequence:
■All unit LEDs light
■Port Status LEDs light in a rapid cycle
When the POST has completed, check the Power/Self Test LED to check that your Switch is operating correctly. Table 4 shows possible colors for the LED.