10CHAPTER 2: SYSTEM DESCRIPTION
Power Supply Module | The front panel of the power supply module has three LEDs (Figure 5). Their |
Visual indicators | descriptions, colors, and functions are shown in Table 2. |
| Figure 5 Power Supply Module Front Panel |
Table 2 LED State Description
Condition | AC OK (green) | DC OK (green) | Fault (Red) |
|
|
|
|
All OK | Lighted | Lighted | Off |
Thermal alarm | Lighted | Off | Off |
(Ambient) |
|
|
|
Thermal alarm (fan fail) | Lighted | Off | Lighted |
Blown AC fuse in unit | Lighted | Off | Lighted |
Low or no AC > 15mS | Off | Off | Off |
(single unit) |
|
|
|
AC not present in any | Off | Off | Off |
power supply module |
|
|
|
Over Voltage Latched | Lighted | Off | Lighted |
shutdown |
|
|
|
Any internal failure | Lighted | Off | Lighted |
|
|
|
|
System Controller | The PoE Power Rack has a system controller at the front of the chassis. Refer to |
| Figure 6. |
| Figure 6 Front Panel of the Controller |
To indicate operational and alarm status, a green LED (RUN) and red LED (ALM) are located on the front panel of the PoE system controller. When the system has an alarm, such as input failure, input
The system controller of the PoE Power Rack has two major functions: