If any of these errors occur, check the RS232 cable, the connectors, and the adapter. Make sure they are in good working order. Verify the communication program is configured correctly. Enter “Y” to try upgrading the flash again. If programming is unsuccessful, the unit should be serviced.

Method 2 – Using the front panel switches with a file copy.

1.Press both the - and + switches on the front panel and power up the UltraView Pro. The UltraView Pro is ready to accept the upgrade file. LED 1 will light indicating the unit is set at 9600 baud. To use 57600 baud, press the + switch, LED 4 will light. Copy the file to the unit. While the file is being copied LED 1 or 4 will flash. Once the file is copied, LED 2 will light.

2.Press and release the + switch, LED 2 flashes off for a brief instant. The flash is now being programmed and verified. LED 3 now lights.

3.Press and release the + switch, LED 3 flashes off for a brief instant. The new firmware is now run and diagnostic information is sent to the on-screen display. Observe the new revision number matches that of the file. LED 4 now lights.

4.Press and release the + switch. LED 1 now lights. The box is now operational and port 1 is selected or the login box is waiting for its password. The flash loading procedure is complete.

Welcome to UltraView Pro

Power on diagnostics

Kernel revision - - - - - -

P3

Hardware type - - - - - -

PC

Kernel checksum - - - -

GOOD

Static ram - - - - - - - - -

GOOD

Com interface - - - - - -

GOOD

Program revision - - - -

UP18

Program checksum - -

GOOD

Total ports found - - - -

08

Config checksum - - - -

GOOD

PC keyboard detected

 

PS/2 mouse detected

 

Figure 11. Power-on diagnostic screen

32ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL

Image 38
Contents Installation and Operations Manual Page Limited Warranty Copyright  Rose Electronics 1990-2002. All rights reservedFCC/IC STATEMENTS, EU Declaration of Conformity Table of Contents Tables AppendicesIntroduction / System overview IntroductionDisclaimer Features Package contentsRose Electronics web site System overviewCompatibility KVM stationMenu system CPU connectionCascading Units Models UltraView Pro modelsUltraView Pro models rear MouseUltraView Pro to KVM station cable CablesUltraView Pro Cables UltraView Pro to CPU cablesConnecting the keyboard, video monitor, and mouse InstallationInstallation single unit Apply power to UltraView ProConnecting the computers Installation Cascading units UltraView Pro to CPUsSlave unit installation Cascading unitsUltraview PRO Installation and Operations Manual Configuration Menus Main configuration menuConfigure system menu Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Configure computer menu USB-PC Configure overlay Configure overlayUltraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Configure security Ultraview PRO Installation and Operations Manual Operation Selecting a computerKeyboard Commands Keyboard commandsType Rackmounting Keyboard command usageReset to factory defaults Serial Port RS232 Firmware updateRS232 Port Ultraview PRO Installation and Operations Manual Good Troubleshooting TroubleshootingUltraview PRO Installation and Operations Manual Maintenance and Repair Service and MaintenanceService Information Technical SupportSafety SafetySafety and EMC Regulatory Statements Ultraview PRO Installation and Operations Manual Appendices YESKIT-ATRX Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Ultraview PRO Installation and Operations Manual Page Stancliff Road Houston, Texas Phone 281