Powerware 5110 Three-phase UPS Products, Feature Focus, Technical Innovation, World-Class Service

Page 11

Powerware

Three-phase UPS Products

Feature Focus

The rise of the Internet, telecom- munications, and other digital technologies has driven greater dependence on both business- to-business and business- to-consumer technologies. Today’s vast and complex digital infrastructure demands bulletproof protection from power disturbances. That’s why customers put their confidence in Powerware solutions to protect their mission-critical applications.

Technical Innovation

Powerware solutions boast a long—and continuing—history of technical innovation. With more than 100 active patents for Powerware solutions, and over 80 patents pending, Eaton has a long tradition of leveraging its technical leadership to provide customers with what

they need most in a power protection solution.

Following are several fea- tures that help differentiate Powerware three-phase UPS solutions:

Power Performance Today’s high power factor load requirements and ris- ing utility costs have placed a premium on power per- formance. Each Powerware three-phase UPS operates at a high efficiency to reduce utility costs, increase reli- ability and extend battery life. Features such as an optional intelligent input filter and innovative input circuit design

keep input current harmonic distortion (THD) low, result- ing in maximum transfer of power between the power source and protected load, and enhancing total compat- ibility with upstream power sources. Output power factors as high as 0.9 easily accommo- date high power

factor load requirements and increase power density. Please see the Powerware 9315, 9320, 9330, and 9390 datasheets for each product’s optional features and technical specifications.

Redundancy and Scalability Field-tested and installed in thousands of installations around the world, Powerware Hot Sync technology has become the global reliability standard. This technology enables a multi-module sys- tem configuration to operate in parallel without the need for inter-module communications, eliminating the system-levelsingle-point-of-failure inherent in traditional parallel configu- rations and maximizes avail- ability. Powerware Hot Sync technology can provide redundancy of N+1, N+2 or higher, and enable up to eight modules to be paralleled for capacity. This technology is available on the Powerware 9315, 9330, and 9390 models.

Battery Management Improper battery maintenance is the number one cause of load loss. Eaton's Powerware solutions feature innovative

battery management systems to take the guesswork out of battery maintenance. Available on almost all of the Powerware 9390s, ABM Technology uses an innovative three-stage charging technique to optimize recharge time and significantly extend battery life. DC Expert® technology, featured on the Powerware 9315, helps avoid load losses caused by unex- pected battery failure by con- tinuously monitoring battery health and dynamically updat- ing information on battery time remaining.

Double-Conversion Topology All Powerware three-phase UPSs employ a double-conver- sion topology to completely isolate the protected load from utility power, providing the best level of power protection available.

World-Class Service

Powerware three-phase solu- tions are backed by a best-in- class services organization.

More than 300 North American field technicians and an $8 mil- lion field inventory of spare parts help ensure each system’s reliability and performance. Our Customer Reliability Center provides 7x24 technical support, dispatch and remote monitor- ing of over 100 UPS and battery alarms. A wide variety of sup- port plans and services, includ- ing on-site startup, corrective and preventive maintenance, and training provide added con- fidence and peace of mind.

www.powerware.com9

Image 11
Contents Product Catalog Powerware Solutions Selecting the Right UPS Powerware UPS Solution OverviewFeatures Single-phase UPS Products350-1550 VA Powerware Series350-700 VA 500-1400 VA PowerwarePowerware 5115 Rackmount Features and Benefits1000-6000 VA Powerware Tower Rackmount1000-2200 VA 700-6000 VA 700-3000 VA15 kVA Powerware 9170+18 kVA Tower 500 VA-18 kVA Rackmount 850 VA-7 kVA Powerware Power Distribution UnitTechnical Innovation Three-phase UPS ProductsFeature Focus World-Class Service10-40 kVA 30-750 kVA40-160 kVA 10-30 kVA Powerware BP Series Industrial UPSPowerware Bpiv 10-60 kVAPF2 Flywheel Three-phase Additional ProductsOther Power Protection Products PowerVision Software Single- and Three-phase Software ProductsPowerware Software Suite For Mission-Critical Infrastructure Power Management Software for Network ShutdownManagement Solution LanSafe SoftwarePeace for mind Powerware CoreLogic Software Development ToolkitSoftware Development tools for system Integrators and software developersNetwork Management System integration soft- ware Powerware Extensions for Network Management SystemsDesktop Power Management Network Monitoring Tool MultiView SoftwareSolutions for the changing global customer landscape Single- and Three-phase Connectivity ProductsPowerware ConnectUPS Family of Ethernet Networking Products Multi-Server Card Multi-Server Card & Relay Interface CardsEaton Services for Powerware Solutions United States