Powerware 9155/Powerware 9355 shown in perspective.
Premium power protection is now easier than ever.
With
Equipment installation is easy, essentially
Scalable architecture meets current and future load requirements.
Powerware 9155 UPSs are available in four models (8, 10, 12, and 15 kVA). Powerware 9355 UPSs come in 10 and 15 kVA models, so you can choose the configuration that most closely meets your capacity requirements and price point.
Powerware 9355 rear view with optional output receptacles
And you can scale from there. Using our signature Powerware Hot Sync paralleling technology, up to three (Powerware 9155) or up to four (Powerware 9355) equivalent UPS modules can be paralleled for extra capacity or redundancy. A 15 kVA UPS, for example, can grow to support loads of up to 45 kVA. There’s no dependence on communications wiring among those UPS modules.
Battery innovations optimize battery performance and service life.
Standard internal batteries provide power until auxiliary power takes over or systems are gracefully shut down. Battery runtime can be extended to hours by adding matching Extended Battery Modules (EBMs).
POWERWARE UPS BACKUP TIMES (IN MINUTES)
|
| UPS | (1) | (2) | (3) | (4) | UPS | (1) | (2) | (3) |
|
| + Internal | EBM | EBM | EBM | EBM | + Internal | EBM | EBM | EBM |
VA | Watt | 32 Battery | 64 | 64 | 64 | 64 | 64 Battery | 96 | 96 | 96 |
15000 | 13500 | 4.6 | 23.0 | 43.0 | 65.1 | 88.6 | 13.3 | 43.0 | 76.7 | 113 |
14500 | 13050 | 4.9 | 24.1 | 45.2 | 68.3 | 93.0 | 14.1 | 45.2 | 80.5 | 119 |
14000 | 12600 | 5.2 | 25.2 | 47.3 | 71.5 | 97.4 | 14.9 | 47.3 | 84.2 | 125 |
13500 | 12150 | 5.5 | 26.4 | 49.4 | 74.7 | 102 | 15.8 | 49.4 | 88.1 | 130 |
13000 | 11700 | 5.8 | 27.6 | 51.6 | 78.1 | 106 | 16.7 | 51.6 | 92.0 | 136 |
12500 | 11250 | 6.1 | 28.8 | 54.0 | 81.6 | 111 | 17.6 | 54.0 | 96.2 | 142 |
12000 | 10800 | 6.5 | 30.2 | 56.5 | 85.5 | 116 | 18.6 | 56.5 | 101 | 149 |
11500 | 10350 | 6.9 | 31.6 | 59.3 | 89.7 | 122 | 19.2 | 59.3 | 106 | 156 |
11000 | 9900 | 7.3 | 33.3 | 62.4 | 94.4 | 129 | 20.2 | 62.4 | 111 | 164 |
10500 | 9450 | 7.8 | 35.1 | 65.9 | 99.6 | 136 | 21.4 | 65.9 | 117 | 174 |
10000 | 9000 | 8.4 | 37.2 | 69.8 | 106 | 144 | 22.6 | 69.8 | 124 | 184 |
9500 | 8550 | 9.1 | 39.6 | 74.2 | 112 | 153 | 24.1 | 74.2 | 132 | 196 |
9000 | 8100 | 9.9 | 42.3 | 79.4 | 120 | 163 | 25.7 | 79.4 | 141 | 209 |
8500 | 7650 | 10.8 | 45.5 | 85.2 | 129 | 175 | 27.6 | 85.2 | 152 | 225 |
8000 | 7200 | 11.9 | 49.1 | 91.9 | 139 | 189 | 29.8 | 91.9 | 164 | 242 |
7500 | 6750 | 13.1 | 53.2 | 99.7 | 151 | 205 | 32.3 | 99.7 | 178 | 263 |
7000 | 6300 | 14.6 | 58.0 | 109 | 164 | 224 | 35.2 | 109 | 194 | 286 |
6500 | 5850 | 16.3 | 63.5 | 119 | 180 | 245 | 38.6 | 119 | 212 | 314 |
6000 | 5400 | 18.4 | 70.0 | 131 | 198 | 270 | 42.5 | 131 | 234 | 346 |
5500 | 4950 | 20.1 | 77.6 | 145 | 220 | 300 | 47.2 | 145 | 259 | 383 |
5000 | 4500 | 22.4 | 86.6 | 162 | 245 | 334 | 52.6 | 162 | 289 | 428 |
4500 | 4050 | 25.2 | 97.4 | 182 | 276 | 376 | 59.2 | 182 | 325 | - |
4000 | 3600 | 28.6 | 110 | 207 | 313 | 426 | 67.1 | 207 | 369 | - |
3500 | 3150 | 32.8 | 127 | 238 | 359 | - | 77.0 | 238 | 423 | - |
3000 | 2700 | 38.3 | 148 | 277 | 418 | - | 89.7 | 277 | - | - |
2500 | 2250 | 45.6 | 176 | 329 | - | - | 107 | 329 | - | - |
Note: Backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.