Gain peace of mind with industry-leading warranty and service plans.
We are so confident about the performance and reliability of the Powerware 9155 and Powerware 9355 UPSs and battery systems that we back them with extensive warranty and service plans.
Warranty coverage. Gain the peace of mind that comes with factory warranty coverage (parts and labor, UPS and batteries) and rapid response from certified support engineers.
Powerware 9155
•2 year limited factory warranty
•10 year pro-rated warranty
•$250,000 load protection guarantee
Powerware 9355
•1 year Service Protection Plan
•7 x 24 emergency response
•On-site start-up support (8 hours/day, 5 days/week)
•3 year battery warranty
•1 year eNotify remote monitoring
Service plans. Beyond the warranty period, service plans are avail- able to match any need—from basic UPS and/or battery support to
all-inclusive packages with unique features, such as advanced remote monitoring with trending, customized capacity planning reports, and power protection audits. Add your choice of guaranteed response times, and you can tailor just the right support package for your needs.
From Eaton—a global leader in power quality solutions.
The culmination of 40 years of R&D excellence, the Powerware 9155 and Powerware 9355 UPSs deliver confidence, and ensure that your organization’s critical electronics are protected by the most reliable, efficient, and full-featured protection available.
Eaton is a global leader in power quality and management solu- tions—the #1 manufacturer of UPSs above 5000 VA (Frost & Sullivan: World UPS Markets, 2004). Eaton’s Power Quality Solutions Operation is headquartered in Raleigh, North Carolina, U.S.
For more information on the Powerware 9155 and the new Powerware 9355 UPS:
www.powerware.com 1-800-356-5794
Powerware 9155 and Powerware 9355 at-a-glance
MODEL SELECTION TABLE - POWERWARE 9155 UPS (8–15 kVA)
| | Power | | | | Unit |
| | Rating2 | Input & Output | Output | Dimensions | Weight3 |
Order Number1 | Description | (kVA/W) | Connection4 | Receptacles | H x W x D (in) | (lb) |
K408110000 | PW9155 Model 8 - 32 Battery (2-high) | 8kVA / 7.2kW | Hardwired | See PDM chart | 32.2 x 12.0 x 32.0 | 352 |
K408120000 | PW9155 Model 8 - 64 Battery (3-high) | 8kVA / 7.2kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 590 |
| | | | | | |
K408130000 | PW9155 Model 8 - 32 Battery with Transformer (3-high) | 8kVA / 7.2kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 558 |
| | | | | | |
K410110000 | PW9155 Model 10 - 32 Battery (2- high) | 10kVA / 9kW | Hardwired | See PDM chart | 32.2 x 12.0 x 32.0 | 352 |
K410120000 | PW9155 Model 10 - 64 Battery (3- high) | 10kVA / 9kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 590 |
| | | | | | |
K410130000 | PW9155 Model 10 - 32 Battery with Transformer (3-high) | 10kVA / 9kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 558 |
| | | | | | |
K412110000 | PW9155 Model 12 - 32 Battery (2-high) | 12kVA / 10.8kW | Hardwired | See PDM chart | 32.2 x 12.0 x 32.0 | 352 |
K412120000 | PW9155 Model 12 - 64 Battery (3-high) | 12kVA / 10.8kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 590 |
| | | | | | |
K412130000 | PW9155 Model 12 - 32 Battery with Transformer (3-high) | 12kVA / 10.8kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 558 |
| | | | | | |
K415110000 | PW9155 Model 15 - 32 Battery (2- high) | 15kVA / 13.5kW | Hardwired | See PDM chart | 32.2 x 12.0 x 32.0 | 352 |
K415120000 | PW9155 Model 15 - 64 Battery (3- high) | 15kVA / 13.5kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 590 |
| | | | | | |
K415130000 | PW9155 Model 15 - 32 Battery with Transformer. (3- high) | 15kVA / 13.5kW | Hardwired | See PDM chart | 47.8 x 12.0 x 32.0 | 558 |
1.50/60 Hz auto-sensing. All models can be used for frequency/phase conversion with derated 80% load, please refer to manual for details.
2.Input voltage 200–240V with neutral or with optional input isolation transformer. Output voltages are user-selectable 100/200, 110/220, 120/240 Vac 180° phase displacement, or 120/208, 127/220 Vac 120° phase displacement.
3.Weight is installed weight, add 47lbs (2-high models) or 50lbs (3-high models) to determine shipping weight.
4.An input neutral is required for all configurations unless the input isolation transformer is used.
MODEL SELECTION TABLE - POWERWARE 9355 UPS (10–15 kVA)
| | Power | | | | Unit |
| | Rating2 | Input & Output | Battery | Dimensions | Weight3 |
Order Number1 | Description | (kVA/W) | Voltages4 | Backup5 | H x W x D (in) | (lb) |
KA1011100000010 | PW9355 with 32-Battery (2-high) | 10 kVA / 9kW | 208/208 | 8 | 32.2 x 12.8 x 33.5 | 373 |
KA1012100000010 | PW9355 with 64-Battery (3-high) | 10 kVA / 9kW | 208/208 | 22 | 47.8 x 12.8 x 33.5 | 609 |
| | | | | | |
KA1011200000010 | PW9355 with 32-Battery (2-high) | 10 kVA / 9kW | 220/2202 | 8 | 32.2 x 12.8 x 33.5 | 373 |
KA1012200000010 | PW9355 with 64-Battery (3-high) | 10 kVA / 9kW | 220/2202 | 22 | 47.8 x 12.8 x 33.5 | 609 |
| | | | | | |
KA1011400000010 | PW9355 with 32-Battery with Transformer (3-high) | 10 kVA / 9kW | 480/208 | 8 | 47.8 x 12.8 x 33.5 | 577 |
| | | | | | |
KA1011600000010 | PW9355 with 32-Battery with Transformer (3-high) | 10 kVA / 9kW | 600/208 | 8 | 47.8 x 12.8 x 33.5 | 57 |
KA1511100000010 | PW9355 with 32-Battery (2-high) | 15 kVA / 13.5kW | 208/208 | 4 | 32.2 x 12.8 x 33.5 | 373 |
| | | | | | |
KA1512100000010 | PW9355 with 64-Battery (3-high) | 15 kVA / 13.5kW | 208/208 | 13 | 47.8 x 12.8 x 33.5 | 609 |
| | | | | | |
KA1511200000010 | PW9355 with 32-Battery (2-high) | 15 kVA / 13.5kW | 220/2202 | 4 | 32.2 x 12.8 x 33.5 | 373 |
KA1512200000010 | PW9355 with 64-Battery (3-high) | 15 kVA / 13.5kW | 220/2202 | 13 | 47.8 x 12.8 x 33.5 | 609 |
| | | | | | |
KA1511400000010 | PW9355 with 32-Battery with Transformer (3-high) | 15 kVA / 13.5kW | 480/208 | 4 | 47.8 x 12.8 x 33.5 | 577 |
| | | | | | |
KA1511600000010 | PW9355 with 32-Battery with Transformer (3-high) | 15 kVA / 13.5kW | 600/208 | 4 | 47.8 x 12.8 x 33.5 | 577 |
1.50/60 Hz auto-sensing.
2.220V units are wye connected 220/127V input and 220/127V output, 3-phase, 4-wire plus ground.
3.Weight is installed weight, add 47 pounds (for 2-high models) or 50 pounds (for 3-high models) to determine shipping weight.
4.An input neutral is required for all configurations unless the input isolation transformer is used.