Powerware 5105 warranty Technical Specifications

Page 2

Technical Specifications

1

 

Advanced Battery Management (ABM™) Technology Doubles Battery Service Life

The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup times of at least half that of new batteries. The illustration to the right shows that batteries that are constantly trickle charged (as are virtually all other UPS batteries on the market today) reach the end of their useful life in less than half the time of batteries charged using ABM. ABM uses a patented three-stage charging technique that not only doubles battery service life, but also optimizes battery recharge time and provides up to a 60-day advanced notifi- cation of pending end of useful battery life.

Data based upon tests performed by an independent battery manufacturer

E L E C T R I C A L IN P U T

Voltage

120 and 230 Vac nominal; see Model Selection Guide for

 

user-selectable voltages

Online

-30%, +20% for nominal voltages; user-selectable

Voltage Range

extended range of -35%, +20%

Nominal Input

50/60 Hz; auto-selection

Frequency

 

Connections

See Model Selection Guide

E L E C T R I C A L OU T P U T

Power Levels

450, 700, 1000, and 1500 VA

Online Efficiency

96%

Online Regulation

-10%, +6%; within Computer Business Equipment

 

Manufacturers Association’s Guidelines (-15%, +10%

 

using extended range)

On Battery

±5% RMS

Regulation

 

Voltage Wave Shape Quasi-sine wave

(on battery)

No Load Sleep Mode Outputs are turned off if <5% load is detected (selectable)

Connections

See Model Selection Guide

Interconnecting 2 ea. IEC-320 (10 A); 230 Vac models only

Cords(cabinet)

P H Y S I C A L

 

 

Dimensions and

See Model Selection Guide

Weight

 

 

Surge Suppression High energy 6500 peak Amp

Audible Noise

Less than 45 dB

Operating Temp

0°C–40°C (32°F–104°F)

 

UL tested at 25°C (77°F)

Operating Humidity 5 to 95% non-condensing

Operating Altitude

Up to 10,000 feet above sea level

Conformance

IEEE 446, NEMA PE 1;

Standards

ANSI C62.41; FCC Class A and B, EN50091-2

 

Class B, NSTA and others

Safety Standards

UL 1778, CSA C22.2, and European standard

 

EN 50091-1

Network Transient In and out RJ11 jack for telephone/modem

Protector

protection (120 Vac models only) or RJ45 for

 

10Base-T network cable; UL497A tested

P O W E R P R O T E C T I O N

Series 5

Protection against power failures, power surges,

Protection

power sags, brownouts, line noise, and a degree of

 

protection against other power problems

1. Due to continuing product improvement programs, specifications are

Interconnecting

4 ea. IEC-320 (10 A)

Cords(rack)

 

Backup Time

See Battery Run Times table

Battery Charging

<4 hrs to 90% usable capacity

subject to change without notice.

Front Panel Display

Battery Type

Sealed, maintenance-free lead-acid

Start-On-Battery

Startup with UPS batteries in absence of utility power

 

IN D I C AT O R S A N D C O N T R O L S

Serial

Intelligent serial communication to provide alarms

Communication

with history, measured parameters, selftest, and many

 

other features.

Front Panel

Ergonomic indicators including wiring fault, battery

Interface LEDs

service, communication operation, system normal; bar

 

graphs for input level, battery charge level, % load

Digital Input/Output

Remote On/Off

Input Voltage Level

Site Wiring Fault

ABM (up to 60-day notice for battery service)

On Button (Start-on-battery)

Battery Level

Load Level

Communications

Off/Standby

Button

Alarm Silence/

Self-test Button