SPECIFICATIONS OF THE TEMPSTAR GP

PERFORMANCE/CAPABILITIES

 

ELECTRICAL REQUIREMENTS

 

OPERATING CAPACITY (RACKS/HOUR)

 

WASH PUMP MOTOR HP

3/4

RACKS PER HOUR

57

CIRCULATOR PUMP MOTOR HP

1/12

DISHES PER HOUR

1425

 

 

 

GLASSES PER HOUR

1425

VOLTS

PHASE

AMPS

 

 

208 - 240

1

6.7

OPERATING CYCLE (SECONDS)

 

110 - 120

1

13.4

WASH TIME

45

 

 

 

RINSE TIME

11

WATER REQUIREMENTS

 

DWELL TIME

2

INLET TEMPERATURE

 

110 -140°F

TOTAL CYCLE TIME

60

GALLONS PER HOUR

 

52.0

 

 

WATER LINE SIZE I.P.S. (Minimum)

3/4”

TANK CAPACITY (GALLONS)

 

DRAIN LINE SIZE I.P.S. (Minimum)

1-1/2”

WASH TANK (MINIMUM)

8.0

FLOW PRESSURE P.S.I. (Optimum)

20

BOOSTER TANK

3.0

 

 

 

 

 

GAS REQUIREMENTS

 

 

WASH PUMP CAPACITY

 

BTU INPUT RATE

 

55,000

GALLONS PER MINUTE

150

INLET LINE PRESSURE (natural gas)

7-10.5” wci

 

 

 

(propane)

11-14” wci

TEMPERATURES

 

FRAME DIMENSIONS

 

 

WASH ---°F (MINIMUM)

150

WIDTH

 

25 3/4”

RINSE ---°F (MINIMUM)

180

DEPTH

 

25 1/4”

 

 

HEIGHT

 

56 3/4”

 

 

STANDARD TABLE HEIGHT

34”

 

 

MAXIMUM INSIDE CLEARANCE

17 1/4”

 

 

RACKS

 

 

 

 

DISH 20” X 20”

 

OPTIONAL

 

 

GLASS & SILVER 20” X 20”

OPTIONAL

1

Page 3
Image 3
Jackson technical manual Specifications of the Tempstar GP