THERMOSTAT ADJUSTMENT PROCEDURE

1)Start up unit

2)Allow to fill, and start warm-up

3)Turn thermostat trim screw Counter Clockwise (CCW) 2 full revolutions

4)Allow wash temperature to reach 170LF on Wash Temperature Gauge

5)Turn thermostat trim screw Clockwise (CW) until flashing Green LED on control board turns off. (The recirculating pump will also turn off).

6)To ensure that the trim screw has not been turned too far CW, turn CCW very slowly until Green LED turns on and once again turn CW very slowly until Green LED goes out.

7)Start normal operation and monitor wash tank temperature.

8)If readjustment is needed repeat steps 5 - 7 until wash tank temperature maintains at 170LF during idle time.

7

Page 9
Image 9
Jackson Tempstar GP technical manual Thermostat Adjustment Procedure