Jackson Tempstar GP Troubleshooting Section, Use Extreme Caution When Testing The Machine, Action

Models: Tempstar GP

1 43
Download 43 pages 35.11 Kb
Page 14
Image 14
TROUBLESHOOTING SECTION

TROUBLESHOOTING SECTION

WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service techni- cian. Many of the tests require that the unit have power to it and live electrical components be exposed.

USE EXTREME CAUTION WHEN TESTING THE MACHINE.

Symptom

Possible Cause

Action

 

 

 

Dishmachine will not run. No power to the

Service breaker tripped.

Reset breaker. If breaker trips again,

unit.

 

immediately contact an electrician.

 

 

 

 

Incoming power lines not installed in control

Install power lines.

 

box.

 

 

 

 

 

Incoming power lines connections not

Tighten connections.

 

tightened.

 

 

 

 

Dishmachine will not run. There is power to

Door switch shorted out or is disconnected.

Check to ensure door switch wires are

the unit.

 

connected correctly. If so, replace door

 

 

switch.

 

 

 

 

Misadjusted or faulty "cycle reset" cam

Replace microswitch.

 

microswitch.

 

 

 

 

Machine runs, but there is not water.

No water supply to machine.

Check to ensure that all water valves are

 

 

open and that water is being supplied to the

 

 

machine at 20 PSI.

 

 

 

 

Incoming water supply solenoid not

Check to ensure that valve is wired

 

operating.

correctly. If so, replace valve.

Dishmachine fills continuously, even when the machine is off.

Incoming water supply solenoid not operating.

Check to ensure that valve is wired correctly. If so, replace valve.

Dishmachine fills continuously, only when the power is on.

Incoming water supply solenoid not operating.

Check to ensure that valve is wired correctly. If so, replace valve.

12

Page 14
Image 14
Jackson Tempstar GP Troubleshooting Section, Use Extreme Caution When Testing The Machine, Symptom, Possible Cause, Action