(2/3)
ELECTRICAL CHARACTERISTICS
Part No. |
| |||||
Rated voltage Eac(V) |
| 250 | 250 | 250 | 250 | |
Rated current(A) |
| 0.5 | 2 | 3 | 6 | |
Test voltage Eac(V)[Between terminal and ground terminal] | 1500 | 1500 | 1500 | 1500 | ||
Insulation resistance(MΩ) |
| 100min. | 100min. | 100min. |
| 100min. |
[DC. 500V, 1min/between terminal and ground terminal] |
| |||||
|
|
|
|
| ||
Leakage current(mA)[250V • 60Hz] |
| 0.5max. | 0.5max. | 0.5max. |
| 0.5max. |
DC resistance(mΩ) |
| 450max. | 350max. | 230max. |
| 60max. |
Operating temperature range(°C)[Including | ||||||
With derating over(°C) |
| 55 | 55 | 55 | 55 | |
Temperature rise(°C) |
| 30max. | 30max. | 30max. |
| 30max. |
Attenuation frequency range | Differential mode at 30dB | 0.45 to 10 | 0.7 to 10 | 0.8 to 10 | 2 to 10 | |
(MHz)[+5 to +35°C] | Common mode at 30dB | 0.1 to 10 | 0.2 to 10 | 0.3 to 10 | 1 to 10 | |
Weight(g) |
| 36 | 36 | 36 | 40 | |
|
|
|
|
|
|
|
Part No. |
|
|
| |||
Rated voltage Eac(V) |
| 250 | 250 | 250 |
|
|
Rated current(A) |
| 1 | 3 | 6 |
|
|
Test voltage Eac(V)[Between terminal and ground terminal] | 1500 | 1500 | 1500 |
|
| |
Insulation resistance(MΩ) |
| 100min. | 100min. | 100min. |
|
|
[DC. 500V, 1min/between terminal and ground terminal] |
|
| ||||
|
|
|
|
| ||
Leakage current(mA)[250V • 60Hz] |
| 0.5max. | 0.5max. | 0.5max. |
|
|
DC resistance(mΩ) |
| 140max. | 120max. | 60max. |
|
|
Operating temperature range(°C)[Including |
|
| ||||
With derating over(°C) |
| 55 | 55 | 55 |
|
|
Temperature rise(°C) |
| 30max. | 30max. | 30max. |
|
|
Attenuation frequency range | Differential mode at 25dB | 0.8 to 10 | 0.8 to 10 | 1.5 to 20 |
|
|
(MHz)[+5 to +35°C] | Common mode at 25dB | 0.6 to 10 | 0.6 to 10 | 3 to 10 |
|
|
Weight(g) |
| 24 | 24 | 24 |
|
|
• All specifications are subject to change without notice.