TDK iQA Series manual Absolute Maximum Ratings, Input Characteristics

Page 4

Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick

Absolute Maximum Ratings:

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.

 

Characteristic

Min

 

Max

 

 

Unit

 

Notes & Conditions

 

Continuous Input Voltage

-0.5

 

80

 

 

Vdc

 

 

 

 

 

 

 

 

 

 

 

 

Transient Input Voltage

---

 

100

 

 

Vdc

100mS max.

 

 

 

 

 

 

 

 

 

 

 

Isolation Voltage

---

 

1500

 

 

Vdc

 

Basic insulation

 

Input to Output

 

 

 

 

 

---

 

1500

 

 

Vdc

 

Basic insulation

 

Input to Baseplate

 

 

 

 

 

---

 

500

 

 

Vdc

 

Operational insulation

 

Output to Baseplate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage Temperature

-55

 

125

 

 

˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Temperature Range (Tc)

-40

 

105*

 

 

˚C

 

Maximum baseplate temperature.

 

 

 

 

 

 

 

 

 

 

*Engineering estimate.

Input Characteristics:

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.

 

Characteristic

Min

 

Typ

 

Max

 

 

Unit

 

Notes & Conditions

 

Operating Input Voltage

36

 

48

 

75

 

 

Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Input Current

---

 

---

 

3.0*

 

 

A

 

Vin = 0 to Vin,max

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn-on Voltage

---

 

34

 

---

 

 

Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn-off Voltage

30*

 

32

 

---

 

 

Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hysteresis

0.5*

 

2

 

---

 

 

Vdc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Startup Delay Time from application of input voltage

---

 

12

 

---

 

 

mS

 

Vo = 0 to 0.1*Vo,nom; On/Off =on,

 

 

 

 

 

 

Io=Io,max, Tc=25˚C

 

 

 

 

 

 

 

 

 

 

 

 

Startup Delay Time from on/off

---

 

10

 

---

 

 

mS

 

Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,

 

 

 

 

 

 

Io=Io,max,Tc=25˚C

 

 

 

 

 

 

 

 

 

 

 

 

Output Voltage Rise Time

---

 

50

 

---

 

 

mS

 

Io=Io,max,Tc=25˚C, Vo=0.1 to

 

 

 

 

 

 

0.9*Vo,nom

 

 

 

 

 

 

 

 

 

 

 

 

Inrush Transient

---

 

---

 

0.1

 

 

A2s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Reflected Ripple

---

 

15

 

---

 

 

mApp

 

See input/output ripple measurement

 

 

 

 

 

 

figure; BW = 5 MHz

 

 

 

 

 

 

 

 

 

 

 

 

Input Ripple Rejection

---

 

50*

 

---

 

 

dB

@120Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

*Engineering Estimate

 

 

 

 

 

 

 

 

 

 

Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required; see the Safety Considerations section of the data sheet.

©2002-2005 TDK Innoveta Inc.

(877) 498-0099

4/19

iQAFullDatasheet080505 2.doc 8/3/2006

 

 

 

 

 

Image 4
Contents Features OptionsOrdering information Product OfferingMechanical Specification Recommended Hole Pattern top view Pin AssignmentInput Characteristics Absolute Maximum RatingsElectrical Data IQA48015A033M 3.3V/2.5V, 15A OutputElectrical Characteristics Typical Vo1 load transient response. Io1 step from 3.75A Trim up tracking trim option IQA48015A050M 5V/3.3V, 15A Output 10/19 11/19 12/19 Thermal Performance Thermal Management Thermal DeratingOperating Information Dual independent Trim Optional Tracking Trim Warranty Input/Output Ripple and Noise MeasurementsReliability QualitySafety Considerations Support@tdkinnoveta.com