Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick
Input/Output Ripple and Noise Measurements
Battery
2 1
12uH
1 2
220uF
esr<0.1
100KHz
2 1
| + |
33uF | Vinput |
esr<0.7 |
|
100KHz | - |
|
|
+
Voutput
-
2 1
1
RLoad
Cext
2
Ground Plane
The input reflected ripple is measured with a current probe and oscilloscope. The ripple current is the current through the 12uH inductor.
The output ripple measurement is made approximately 9 cm (3.5 in.) from the power module using an oscilloscope and BNC socket. The capacitor Cext is located about 5 cm (2 in.) from the power module; its value varies from code to code and is found on the electrical data page for the power module of interest under the ripple & noise voltage specification in the Notes & Conditions column.
Reliability
The power modules are designed using TDK Innoveta’s stringent design guidelines for component derating, product qualification, and design reviews. Early failures are screened out by both
Improper handling or cleaning processes can adversely affect the appearance, testability, and reliability of the power modules. Contact Innoveta technical support for guidance regarding proper handling, cleaning, and soldering of TDK Innoveta’s power modules.
Quality
TDK Innoveta’s product development process incorporates advanced quality planning tools such as FMEA and Cpk analysis to ensure designs are robust and reliable. All products are assembled at ISO certified assembly plants.
Warranty
TDK Innoveta’s comprehensive line of power solutions includes efficient,
℡ (877) | 18/19 | ||
iQAFullDatasheet080505 2.doc 8/3/2006 | |||
|
| ||
|
|
|