SUPER MICRO Computer 6015B-Ni manual Checking the Serverboard Setup

Page 24

SUPERSERVER 6015B-Ni Manual

2-5 Checking the Serverboard Setup

After you install the 6015B-Ni in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.

1.Accessing the inside of the 6015B-Ni (see Figure 2-5)

First, release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.

2.Check the CPUs (processors)

You should have one or two processors already installed into the system board. Each processor needs its own heatsink. See Chapter 5 for instructions on pro- cessor and heatsink installation.

3.Check the system memory

Your 6015B-Ni server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.

4.Installing add-on cards

If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.

5.Check all cable connections and airflow

Make sure all power and data cables are properly connected and not block- ing the chassis airfl ow. See Chapter 5 for details on cable connections. Also, check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the serverboard area of the chassis.

2-8

Image 24
Contents Super Manual Revision Release Date June 20 Preface About This ManualManual Organization System Safety Advanced Serverboard SetupAdvanced Chassis Setup BiosPreface Table of Contents System Safety Advanced Serverboard SetupAdvanced Chassis Setup SgpioBios AppendicesPage Chapter Introduction OverviewServerboard Features ProcessorsMemory Serial ATAOther Features ATI Graphics ControllerServer Chassis Features System PowerControl Panel BackplaneContacting Super Micro HeadquartersEurope Asia-PacificSuperserver 6015B-Ni Manual Chapter Server Installation Preparing for SetupUnpacking the System Choosing a Setup Location Rack PrecautionsServer Precautions Rack Mounting Considerations Installing the System into a Rack Identifying the Sections of the Rack RailsInstalling the Chassis Rails Installing the Rack RailsInstalling the Server into the Rack Installing the Server into a RackInstalling the Server into a Telco Rack Installing the Server into a Telco RackChecking the Serverboard Setup Checking the Drive Bay Setup Accessing the drive baysSupplying power to the system Check the airflowSuperserver 6015B-Ni Manual Chapter System Interface Control Panel ButtonsControl Panel LEDs Universal Information LED StatesPage Superserver 6015B-Ni Manual Chapter System Safety Electrical Safety PrecautionsGeneral Safety Precautions ESD Precautions Operating Precautions Installing the Onboard BatteryChapter Advanced Serverboard Setup PrecautionsHandling the Serverboard UnpackingProcessor and Heatsink Installation Installing the ProcessorPage Installing the Heatsink Removing the HeatsinkConnecting Cables Connecting Data CablesConnecting Power Cables Connecting the Control Panel Front Control Panel Header Pins JF1Installing Memory Dimm Installation See FigureI/O Ports Memory SupportInstalling Dimm into Slot PCI card installation Adding PCI CardsPCI Expansion Slots Serverboard Details Super X7DBU LayoutJumper Description Default Setting Connector DescriptionX7DBU Quick Reference Other DescriptionConnector Definitions HDD LED Universal Information LEDPower Fail LED Reset ButtonPower Button Universal Serial Bus USB0/1Universal Serial Bus Headers Serial PortsFan Headers Power LED/Speaker Chassis IntrusionATX PS/2 Keyboard and PS/2 Mouse Ports Overheat LEDWake-On-LAN Wake-On-RingAlarm Reset JAR JLAN1/2 Ethernet PortsJumper Settings VGA Enable/DisableExplanation Jumpers Cmos ClearLAN Enable/Disable Watch Dog Enable/DisableI2C Enable/Disable Onboard Indicators LAN1/LAN2 LEDsFloppy Connector Floppy, IDE and Sata Drive ConnectionsIDE Connector Sata PortsPage Chapter Advanced Chassis Setup Static-Sensitive DevicesTools Required Control Panel Chassis Front and Rear ViewsInstalling a new fan System FansSystem Fan Failure Replacing System FansDrive Bay Installation/Removal Accessing the Drive BaysInstalling Components in the 3.5 Drive Bays Drive bay configurationMounting components in the drive bays Power Supply Power Supply FailureRemoving/Replacing the Power Supply Removing the power supplyRemoving/Replacing the Power Supply Superserver 6015B-Ni Manual System Bios How To Change the Configuration DataStarting the Setup Utility ChapterRunning Setup Main Bios SetupPress the Delete key to enter Setup Main Bios Setup Menu Main Setup Features Bios DateSystem Time System DateIDE Channel 0 Master/Slave and Secondary IDE Master/Slave TypeLBA Mode Control Transfer ModeUltra DMA Mode Multi-Sector TransfersNative Mode Operation Sata Controller ModeSerial ATA Sata RAID Enable Parallel ATAAdvanced Setup Power Button Behavior Power Loss ControlMemory Cache Cache System Bios Area Cache Video Bios AreaDefault Primary Video Adapter Cache Base 512K-640KCache Extended Memory Discrete Mtrr AllocationEmulated IRQ Solutions PCI Parity Error ForwardingPCI Fast Delayed Transaction Reset Configuration DataEnable Master Latency TimerLarge Disk Access Mode Serr Signal ConditionHigh Temperature Dram Operation Crystal Beach FeaturesClock Spectrum Feature Branch 1 Rank Interleaving & SparingEnabling Multi-Media Timer USB FunctionLegacy USB Support Advanced Processor OptionsIntel Eist Support Available when supported by the CPU Device ConfigurationKBC Clock Input Serial Port aInterrupt Serial Port BMode Floppy Disk ControllerDMI Event Logging Event Log ValidityEvent Log Capacity View DMI Event LogConsole Redirection COM Port AddressBaud Rate Console TypeCPU Temperature Threshold Hardware Monitor LogicVoltage Monitoring Fan Speed Control ModesTemperature Monitoring Available if supported by the CPU System Event Logging Clear System Event LoggingExisting Event Log Number Event Log ControlOS Boot Watch Dog Timer for Loading OS MinutesSystem Event Log/System Event Log List Mode Time Out OptionRealtime Sensor Data Supervisor Password Is User Password IsSet Supervisor Password Set User PasswordBoot Password on BootBoot Priority Order/Excluded from Boot Orders Exit Page Appendix a Bios Post Messages System Cmos checksum bad Default configuration used System timer errorReal time clock error Check date and time settingsSystem cache error Cache disabled Fail-Safe Timer NMI FailedAllocation Error for device Entering SetupPS/2 Mouse Boot Summary Screen Fixed Disk nInvalid System Configuration Data Device IRQ conflictPress F1 to resume, F2 to Setup, F3 for previous Press F2 to enter SetupSystem Bios shadowed Video Bios shadowedPage Appendix B Bios Post Codes Recoverable Post ErrorsTerminal Post Errors Post Code DescriptionPost Code Description Post Code Description Post Code Description Following are for boot block in Flash ROM Page Appendix C Software Installation Important NotesSerial ATA Sata Introduction to Intel ESB2 Serial RAIDConfiguring Bios for Sata RAID Functions Native Mode RAID ConfigurationsIntel Matrix Storage Using the Intel ESB2 Sata RAID Utility Program Creating, Deleting and Resetting RAID VolumesCreating a RAID 0 Volume Creating a RAID 1 Volume Creating a RAID 10 RAID 1+ RAID Creating a RAID 5 Set Parity Deleting a RAID Volume Resetting to Non-RAID and Resetting a RAID HDD Exiting the Intel Matrix Storage Manager UtilityInstalling Windows XP/2000/2003 for RAID Systems New Operating System-Windows XP/2000/2003 InstallationInstalling the Operating System and other Software Programs Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control Page Appendix D System Specifications Weight Power SupplySystem Cooling System Input Requirements