COMPLIANCES

Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:

Power Cord Set

U.S.A. and Canada

The cord set must be UL-approved and CSA certified.

 

 

 

The minimum specifications for the flexible cord are:

 

- No. 18 AWG - not longer than 2 meters, or 16 AWG.

 

- Type SV or SJ

 

- 3-conductor

 

 

 

The cord set must have a rated current capacity of at least 10 A

 

 

 

The attachment plug must be an earth-grounding type with NEMA

 

5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

 

 

Denmark

The supply plug must comply with Section 107-2-D1, Standard

 

DK2-1a or DK2-5a.

 

 

Switzerland

The supply plug must comply with SEV/ASE 1011.

 

 

U.K.

The supply plug must comply with BS1363 (3-pin 13 A) and be fitted

 

with a 5 A fuse which complies with BS1362.

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of

 

type HO3VVF3GO.75 (minimum).

 

 

Europe

The supply plug must comply with CEE7/7 (“SCHUKO”).

 

 

 

The mains cord must be <HAR> or <BASEC> marked and be of

 

type HO3VVF3GO.75 (minimum).

 

 

 

IEC-320 receptacle.

 

 

Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:

AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié.

Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).

Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité.

Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entrée d’appareil EN 60320/IEC 320.

La prise secteur doit se trouver à proximité de l’appareil et son accès doit être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant son cordon électrique au niveau de cette prise.

L’appareil fonctionne à une tension extrêmement basse de sécurité qui est conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.

vi

Image 10
Contents TigerSwitch 10/100 Page TigerSwitch 10/100 Installation Guide Trademarks Limited Warranty Limited Warranty Industry Canada Class a CompliancesFCC Class a Japan Vcci Class aCE Mark Declaration of Conformance for EMI and Safety EEC Power Cord Safety Safety ComplianceWarnhinweis Faseroptikanschlüsse Optische Sicherheit Power Cord Set Vii France et Pérou uniquementViii Audience Environmental StatementPurpose Related PublicationsCompliances Table of Contents Making Network Connections XiiGlossary Index XiiiXiv Tables Xvi Figures XviiXviii FiguresOverview Front and Rear PanelsNetwork Management Options Switch ArchitectureDescription of Hardware 10/100BASE-T PortsSFP Slots Port and System Status LEDsPort Status LEDs System LEDsPower Supply Socket System Status LEDsExpandability Features and BenefitsConnectivity PerformanceManagement About the Tigerswitch Introduction to Switching Chapter Network PlanningApplication Examples Collapsed BackboneNetwork Aggregation Plan Network Aggregation PlanRemote Connections with Fiber Cable Remote Connections with Fiber CableMaking Vlan Connections Making Vlan ConnectionsApplication Notes Installing the Switch Selecting a SiteEthernet Cabling RJ-45 ConnectionsPackage Contents Equipment ChecklistOptional Rack-Mounting Equipment Mounting Rack MountingAttaching the Brackets Desktop or Shelf Mounting Attaching the Adhesive FeetInstalling an Optional SFP Transceiver Installing an SFP Transceiver into a SlotConnecting to a Power Source Power SocketConnecting to the Console Port Wiring Map for Serial CableInstalling the Switch Twisted-Pair Devices Connecting Network DevicesChapter Making Network Connections Cabling GuidelinesConnecting to PCs, Servers, Hubs and Switches Making Twisted-Pair ConnectionsNetwork Wiring Connections Network Wiring ConnectionsFiber Optic SFP Devices Making Fiber Port Connections 1000BASE-T Cable Requirements Connectivity RulesMbps Gigabit Ethernet Collision Domain Mbps Fast Ethernet Collision Domain Micron 70 100 km Single-mode fiber 43.5 62.1 milesCable Labeling and Connection Records Mbps Ethernet Collision DomainAppendix a Troubleshooting Diagnosing Switch IndicatorsInstallation Power Supply ProblemsIn-Band Access Appendix B Cables Twisted-Pair Cable and Pin Assignments10BASE-T/100BASE-TX Pin Assignments Table B-1 10/100BASE-TX MDI and MDI-X Port PinoutsStraight-Through Wiring Crossover WiringFigure B-3 Crossover Wiring 1000BASE-T Pin AssignmentsCable Testing for Existing Category 5 Cable Adjusting Existing Category 5 Cabling to Run 1000BASE-T Fiber StandardsAppendix C Specifications Physical CharacteristicsSwitch Features Standards Management FeaturesCompliances Warranty SafetyImmunity Table D-1 TigerSwitch 10/100 Products and Accessories Appendix D Ordering InformationOrdering Information Appendix E German Instructions Eine Site Auswählen Selecting a SiteMontage Rack Mounting Instructions Rack-MontageAnschluss an eine Stromquelle Connecting to a Abbildung 3-6 StromanschlüsseGerman Instructions 1000BASE-T GlossaryGlossary-1 Auto-NegotiationGlossary-2 Glossary-3 Glossary-4 Transmission Control Protocol/Internet Protocol TCP/IP Glossary-5Virtual LAN Vlan Glossary-6 Index Index-1Index-2 Index-3 Index-4 Page For Technical SUPPORT, Call

SMC6128L2 specifications

The SMC Networks SMC6128L2 is a highly versatile and efficient Layer 2 Ethernet switch designed to cater to the connectivity needs of both small and medium-sized enterprises as well as larger networks. Known for its reliability and performance, the SMC6128L2 offers a range of features that make it suitable for various applications.

One of the standout characteristics of the SMC6128L2 is its capacity to support 28 ports, of which 24 are 10/100/1000 Mbps Gigabit Ethernet ports. These ports facilitate high-speed data transfer, making the switch ideal for bandwidth-intensive tasks, such as video streaming, online gaming, and large file transfers. The remaining four ports provide Gigabit SFP slots that allow for additional expansion and flexibility, accommodating different types of connections depending on network requirements.

The SMC6128L2 is equipped with advanced management features that enable seamless control and configuration of the switch. The device supports various management protocols, including SNMP, RMON, and WEB management, allowing administrators to monitor network performance in real-time, configure settings, and troubleshoot issues efficiently.

Another prominent technology incorporated in the SMC6128L2 is VLAN (Virtual Local Area Network) support. This functionality allows users to segment networks into distinct zones to enhance security and improve traffic management. By enabling traffic isolation, VLANs facilitate better control over network resources and can significantly reduce broadcast storms that may impair network performance.

Quality of Service (QoS) is also an essential feature of the SMC6128L2, allowing the prioritization of critical network traffic to ensure that essential applications maintain their performance levels, particularly during peak usage times. This capability is beneficial for organizations relying on real-time applications such as VoIP or video conferencing.

The switch supports various security features, including port security and MAC address filtering, which help mitigate unauthorized access and safeguard sensitive data. Its robust design features a fanless architecture for quiet operation, making it well-suited for office environments.

Overall, the SMC Networks SMC6128L2 is an effective solution for organizations looking to invest in a robust, efficient, and feature-rich switching system. Its combination of high-performance capabilities, management flexibility, and security features positions it as a reliable choice for a wide range of networking needs.