SMC Networks SMC6128L2 manual CE Mark Declaration of Conformance for EMI and Safety EEC

Page 8

COMPLIANCES

CE Mark Declaration of Conformance for EMI and Safety (EEC)

SMC contact for these products in Europe is:

SMC Networks Europe, Edificio Conata II,

Calle Fructuós Gelabert 6-8, 2o, 4a,

08970 - Sant Joan Despí, Barcelona, Spain.

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

• Limit class A according to EN 55022:1998

 

• Limit class A for harmonic current emission according to EN 61000-3-2/

 

1995

 

• Limitation of voltage fluctuation and flicker in low-voltage supply system

 

according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

 

• Electrostatic Discharge according to EN 61000-4-2:1995

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to EN 61000-4-3:1996

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC

 

power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency fields:

 

EN 61000-4-6:1996 (0.15 - 80 MHz with

 

1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

EN60950-1:2001

Warning: Do not plug a phone jack connector in the RJ-45 port. This may damage this device.

Attention: Les raccordeurs ne sont pas utilisés pour le système téléphonique!

iv

Image 8
Contents TigerSwitch 10/100 Page TigerSwitch 10/100 Installation Guide Trademarks Limited Warranty Limited Warranty Compliances FCC Class aIndustry Canada Class a Japan Vcci Class aCE Mark Declaration of Conformance for EMI and Safety EEC Warnhinweis Faseroptikanschlüsse Optische Sicherheit Safety CompliancePower Cord Safety Power Cord Set Vii France et Pérou uniquementViii Environmental Statement PurposeAudience Related PublicationsCompliances Table of Contents Making Network Connections XiiGlossary Index XiiiXiv Tables Xvi Figures XviiXviii FiguresOverview Front and Rear PanelsSwitch Architecture Description of HardwareNetwork Management Options 10/100BASE-T PortsSFP Slots Port and System Status LEDsPort Status LEDs System LEDsPower Supply Socket System Status LEDsFeatures and Benefits ConnectivityExpandability PerformanceManagement About the Tigerswitch Introduction to Switching Chapter Network PlanningApplication Examples Collapsed BackboneNetwork Aggregation Plan Network Aggregation PlanRemote Connections with Fiber Cable Remote Connections with Fiber CableMaking Vlan Connections Making Vlan ConnectionsApplication Notes Installing the Switch Selecting a SiteEthernet Cabling RJ-45 ConnectionsOptional Rack-Mounting Equipment Equipment ChecklistPackage Contents Mounting Rack MountingAttaching the Brackets Desktop or Shelf Mounting Attaching the Adhesive FeetInstalling an Optional SFP Transceiver Installing an SFP Transceiver into a SlotConnecting to a Power Source Power SocketConnecting to the Console Port Wiring Map for Serial CableInstalling the Switch Connecting Network Devices Chapter Making Network ConnectionsTwisted-Pair Devices Cabling GuidelinesConnecting to PCs, Servers, Hubs and Switches Making Twisted-Pair ConnectionsNetwork Wiring Connections Network Wiring ConnectionsFiber Optic SFP Devices Making Fiber Port Connections Mbps Gigabit Ethernet Collision Domain Connectivity Rules1000BASE-T Cable Requirements Mbps Fast Ethernet Collision Domain Micron 70 100 km Single-mode fiber 43.5 62.1 milesCable Labeling and Connection Records Mbps Ethernet Collision DomainAppendix a Troubleshooting Diagnosing Switch IndicatorsIn-Band Access Power Supply ProblemsInstallation Appendix B Cables Twisted-Pair Cable and Pin Assignments10BASE-T/100BASE-TX Pin Assignments Table B-1 10/100BASE-TX MDI and MDI-X Port PinoutsStraight-Through Wiring Crossover WiringFigure B-3 Crossover Wiring 1000BASE-T Pin AssignmentsCable Testing for Existing Category 5 Cable Adjusting Existing Category 5 Cabling to Run 1000BASE-T Fiber StandardsAppendix C Specifications Physical CharacteristicsSwitch Features Compliances Management FeaturesStandards Immunity SafetyWarranty Table D-1 TigerSwitch 10/100 Products and Accessories Appendix D Ordering InformationOrdering Information Appendix E German Instructions Eine Site Auswählen Selecting a SiteMontage Rack Mounting Instructions Rack-MontageAnschluss an eine Stromquelle Connecting to a Abbildung 3-6 StromanschlüsseGerman Instructions Glossary Glossary-11000BASE-T Auto-NegotiationGlossary-2 Glossary-3 Glossary-4 Virtual LAN Vlan Glossary-5Transmission Control Protocol/Internet Protocol TCP/IP Glossary-6 Index Index-1Index-2 Index-3 Index-4 Page For Technical SUPPORT, Call

SMC6128L2 specifications

The SMC Networks SMC6128L2 is a highly versatile and efficient Layer 2 Ethernet switch designed to cater to the connectivity needs of both small and medium-sized enterprises as well as larger networks. Known for its reliability and performance, the SMC6128L2 offers a range of features that make it suitable for various applications.

One of the standout characteristics of the SMC6128L2 is its capacity to support 28 ports, of which 24 are 10/100/1000 Mbps Gigabit Ethernet ports. These ports facilitate high-speed data transfer, making the switch ideal for bandwidth-intensive tasks, such as video streaming, online gaming, and large file transfers. The remaining four ports provide Gigabit SFP slots that allow for additional expansion and flexibility, accommodating different types of connections depending on network requirements.

The SMC6128L2 is equipped with advanced management features that enable seamless control and configuration of the switch. The device supports various management protocols, including SNMP, RMON, and WEB management, allowing administrators to monitor network performance in real-time, configure settings, and troubleshoot issues efficiently.

Another prominent technology incorporated in the SMC6128L2 is VLAN (Virtual Local Area Network) support. This functionality allows users to segment networks into distinct zones to enhance security and improve traffic management. By enabling traffic isolation, VLANs facilitate better control over network resources and can significantly reduce broadcast storms that may impair network performance.

Quality of Service (QoS) is also an essential feature of the SMC6128L2, allowing the prioritization of critical network traffic to ensure that essential applications maintain their performance levels, particularly during peak usage times. This capability is beneficial for organizations relying on real-time applications such as VoIP or video conferencing.

The switch supports various security features, including port security and MAC address filtering, which help mitigate unauthorized access and safeguard sensitive data. Its robust design features a fanless architecture for quiet operation, making it well-suited for office environments.

Overall, the SMC Networks SMC6128L2 is an effective solution for organizations looking to invest in a robust, efficient, and feature-rich switching system. Its combination of high-performance capabilities, management flexibility, and security features positions it as a reliable choice for a wide range of networking needs.