SMC Networks SMC7824M/FSW manual CE Mark Declaration of Conformance for EMI and Safety EEC, Viii

Page 8

COMPLIANCES

CE Mark Declaration of Conformance for EMI and Safety (EEC)

SMC contact for these products in Europe is:

SMC Networks Europe, Edificio Conata II,

Calle Fructuós Gelabert 6-8, 2o, 4a,

08970 - Sant Joan Despí, Barcelona, Spain.

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

• Limit class A according to EN 55022:1998

 

• Limit class A for harmonic current emission according to

 

EN 61000-3-2/1995

 

• Limitation of voltage fluctuation and flicker in low-voltage supply

 

system according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

 

• Electrostatic Discharge according to EN 61000-4-2:1995

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to EN 61000-4-3:1996

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/

 

DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency

 

fields: EN 61000-4-6:1996 (0.15 - 80 MHz with 1 kHz AM 80%

 

Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

EN 61000-4-8:1993

 

(1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

• EN 60950-1:2001

Warning: Do not plug a phone jack connector in the RJ-45 port. This may damage this device.

Attention: Les raccordeurs ne sont pas utilisés pour le système téléphonique!

viii

Image 8
Contents TigerAccess 10/100 Page TigerAccess 10/100 Installation Guide Trademarks Limited Warranty SMC Networks, Inc Tesla Irvine, CA Compliances FCC Class aIndustry Canada Class a Japan Vcci Class aCE Mark Declaration of Conformance for EMI and Safety EEC ViiiWarnhinweis Faseroptikanschlüsse Optische Sicherheit Safety ComplianceAustralia AS/NZS 3548 1995 Class a Power Cord Safety Power Cord SetFrance et Pérou uniquement PSE Alarm XiiXiii Xiv Table of Contents Making Network Connections XviTroubleshooting SpecificationsCables German InstructionsXviii Tables XixFigures Chapter About Tigeraccess Switch OverviewSwitch Architecture Front Panel100BASE-BX SC Fiber Ports Description of HardwareNetwork Management Options Console Port 100BASE-TX and 1000BASE-T Ports100BASE-TX Management Port Optional SFP Transceivers Alarm Interface PortSFP Slots Port and System Status LEDs Port and System LEDsPort and System Status LEDs LEDFan Tray Fan TrayPower Modules Optional Power ModulesOptional Media Extender Module 1000BASE Combo ModuleFeatures and Benefits ConnectivityExpandability PerformanceManagement Chapter Network Planning Fiber-To-The-Home FtthConnection Examples Downlink Fiber Connections Downlink Fiber ConnectionsUplink Connections Uplink Fiber ConnectionsManagement Connections Management Port ConnectionsPrivate Vlan Connections Private Vlan ConnectionsApplication Notes Network Planning Installing the Switch Selecting a SiteEthernet Cabling RJ-45 ConnectionsOptional Rack-Mounting Equipment Equipment ChecklistPackage Contents Mounting Rack MountingInstalling the Switch in a Rack Desktop or Shelf MountingAttaching the Adhesive Feet Installing an Optional Module into the Switch Installing an Optional ModuleInstalling an Optional SFP Transceiver Inserting an SFP Transceiver into a SlotGrounding the Chassis Connecting to a Power Source Connecting DC PowerConnecting to a Power Source DC Plug Connections Connecting AC Power AC Power ReceptacleSerial Cable Wiring Connecting to the Console PortWiring Map for Serial Cable Connecting to the Alarm Port 10 Alarm Port D-15 Pin-OutWiring Map for Alarm Cable Alarm Cable Wiring11 External Alarm I/O Connections Installing the Switch Connecting Network Devices Chapter Making Network ConnectionsTwisted-Pair Devices Cabling GuidelinesConnecting to PCs, Servers, Hubs and Switches Making Twisted-Pair ConnectionsNetwork Wiring Connections Network Wiring ConnectionsFiber Optic Devices Making Connections to 100BASE-BX Ports and SFP Transceivers Connectivity Rules 1000BASE-T Cable RequirementsMbps Gigabit Ethernet Cable Lengths Maximum 1000BASE-T Gigabit Ethernet Cable LengthMaximum 1000BASE-SX Gigabit Ethernet Cable Length Maximum 1000BASE-LX Gigabit Ethernet Cable LengthMbps Fast Ethernet Cable Lengths Mbps Ethernet Cable LengthsMaximum Fast Ethernet Cable Length Maximum 100BASE-BX Fast Ethernet Cable LengthCable Labeling and Connection Records Making Network Connections Table A-1 Diagnosing Switch Indicators Appendix a TroubleshootingDiagnosing Switch Indicators Troubleshooting In-Band Access Power and Cooling ProblemsInstallation Troubleshooting Appendix B Cables Twisted-Pair Cable and Pin Assignments10BASE-T/100BASE-TX Pin Assignments Table B-1 10/100BASE-TX MDI and MDI-X Port PinoutsStraight-Through Wiring Figure B-2 Straight-through WiringCrossover Wiring Figure B-3 Crossover Wiring1000BASE-T Pin Assignments Table B-2 1000BASE-T MDI and MDI-X Port PinoutsCable Testing for Existing Category 5 Cable Adjusting Existing Category 5 Cabling to Run 1000BASE-TFiber Standards Cables Appendix C Specifications Physical CharacteristicsSwitching Database WeightTemperature Power SupplySwitch Features Management FeaturesStandards CompliancesEmissions ImmunityExtender Modules Extender Modules Appendix D German Instructions Eine Site Auswählen Selecting a SiteMontage Rack Mounting Instructions Rack-MontageDas Erden des Gehäuses Grounding the ChassisAnschluss an eine Stromquelle Anschluss an GleichstromAnschluss AN Eine Stromquelle Connecting to a Power Source Figure D-1 Gleichstromanschlüsse Wechselstromanschluss Figure D-2 Wechselstromanschluss Table E-1 TigerAccess 10/100 Products and Accessories Appendix E Ordering InformationOrdering Information 1000BASE-T GlossaryGlossary-1 Glossary-2 Glossary-3 Glossary-4 Virtual LAN Vlan Glossary-5Transmission Control Protocol/Internet Protocol TCP/IP Glossary-6 Index Index-1Index-2 Index-3 SFPIndex-4 Page For Technical SUPPORT, Call

SMC7824M/FSW specifications

The SMC Networks SMC7824M/FSW is a robust and versatile managed switch designed for small to medium-sized enterprises that require reliable networking solutions for their growing needs. This switch is part of SMC's commitment to providing innovative networking products that deliver superior performance and flexibility.

One of the main features of the SMC7824M/FSW is its 24-port configuration, which provides ample connectivity for a variety of devices within a network. The switch supports both 10/100 Mbps Fast Ethernet and 10/100/1000 Mbps Gigabit Ethernet connections, allowing for seamless integration of multiple devices ranging from legacy systems to modern high-speed applications. This flexibility is crucial for businesses looking to extend the life of existing equipment while still adopting new technologies.

The SMC7824M/FSW is equipped with advanced Layer 2 management capabilities, including VLAN (Virtual Local Area Network) support, which enables network administrators to segment traffic for improved performance and security. Additionally, it supports Spanning Tree Protocol (STP) and Rapid Spanning Tree Protocol (RSTP), which ensures loop-free network topology and enhances network stability.

Another significant feature is the switch’s Quality of Service (QoS) functionality, allowing for prioritization of critical data traffic. This is particularly beneficial for voice over IP (VoIP) and video conferencing applications, where latency and jitter must be minimized to ensure optimal performance. With QoS, businesses can maintain high levels of service, even as network demands increase.

The SMC7824M/FSW also includes features such as port mirroring for traffic analysis and troubleshooting, Link Aggregation for increased bandwidth and redundancy, and an easy-to-use web-based interface for straightforward configuration and management. This ease of use makes it an excellent choice for IT administrators who may not have extensive networking experience.

In addition to its extensive feature set, the SMC7824M/FSW is designed with energy efficiency in mind. It complies with IEEE 802.3az Energy Efficient Ethernet standards, allowing it to consume less power during periods of low traffic, thus reducing operational costs.

In summary, the SMC Networks SMC7824M/FSW switch is a powerful solution that combines flexibility, advanced management features, and energy efficiency, making it an ideal choice for businesses looking to enhance their networking capabilities while remaining cost-effective. Its comprehensive set of features ensures that it can meet the demands of modern network environments.