Electrolux 55 GLXA Main Oven, Second Oven, General, Important Safety Requirements

Models: 55 GLXA

1 48
Download 48 pages 60.4 Kb
Page 41
Image 41

S O N A T A 5 5 G L X a

MAIN OVEN

Natural Gas

L.P. Gas

Heat Input

2.4kW (8189Btu/h)

2.4kW (172.4 g/h)

Injector Marking

108

78

Flame Supervision Device

Diamond'H' GSD 100/28

Diamond 'H' GSD-100-30

Thermostat

Diamond'H' 1100 -147/B2

Diamond'H' 1100-148/B2

Thermostat By-Pass Marking

69

78

SECOND OVEN

Natural Gas

L. P. Gas

Heat Input

2.4kW (8189 Btu/h)

2.4kW (172.4g/h)

Injector Marking

108

78

Flame Supervision Device

Diamond 'H' GSD 100/31

Diamond 'H' Ref GSD-100/34

Dual Control

Sourdillon 60112/982

Sourdillon 60525/982

Dual Control By-pass

Fixed Internal

Fixed Internal

GENERAL

 

 

Ignition

H. T. Spark

 

Spark Gap

3-4mm

 

IMPORTANT - SAFETY REQUIREMENTS

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations Current Editions. Detailed recommendations are contained in the following British Standard Codes of Practice - BS. 6172, BS.5440: Part 2 and B.S.6891. All British Standards must be 'Current Editions'.

PROVISION FOR VENTILATION

The room containing the appliance should have an air supply in accordance with BS.5440: Part 2 Current Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as well. For room volumes up to 5m³ an air vent of 100 cm² is required; for room volumes between 5m³ and 10m³ an air vent of 50cm² is required. If the room has a door that opens directly to the outside, no air vent is required. For room volumes that exceed 11m³ no air vent is required. If there are other fuel burning appliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisite air vent requirements. The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that the kitchen is well ventilated: keep natural ventilation holes open or install a mechanical ventilation device (mechanical extractor hood).

Prolonged intensive use of the appliance may call for additional ventilation, for example opening of a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present.