Sierra Monitor Corporation EX250-SEN1 instruction manual Do not operate beyond specification range

Page 3

SAFETY

The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.

Please check that you fully understand the definitions of the following messages

( symbols ) before going on to read the body of this manual, and always follow the instructions.

Please also read the instruction manuals etc. of related machines and equipments and understand the contents before use.

IMPORTANT MESSAGES

Read this manual and follow its instructions. Signal words such as WARNING, CAUTION and NOTE will be followed by important safety information that must be carefully reviewed.

Indicates a potentially hazardous situation that could result in death or severe injury if you do not follow instructions.

 

Indicates a potentially hazardous situation that, if not avoided,

 

may result in minor injury or moderate injury.

NOTE

Gives you helpful information.

Do not disassemble,

modify ( including modification of printed circuit board ) or repair.

Otherwise injury or failure can result.

Do not operate beyond specification range.

Otherwise fire, malfunction or damage to the reduced wiring system can result. Confirm the specifications before operation.

Do not operate in atmosphere of flammable/explosive/corrosive gas.

Otherwise fire, explosion or corrosion can result.

This reduced wiring system is not explosion-proof type.

For use in interlock circuit:

Provide double interlock system by adding different type of protection ( such as mechanical protection ).

Check that the interlock circuit is working normally.

Otherwise accident caused by malfunction can result.

Before performing maintenance:

Turn off power supply.

Stop air supply, exhaust compressed air in piping, and confirm the release to atmosphere.

Otherwise injury can result.

Conduct proper functional inspection after completing maintenance.

In the case of abnormality such as unit does not work normally, stop the operation. Otherwise safety cannot be assured due to unintended malfunction.

Provide grounding to improve safety and noise resistance of reduced wiring system.

Provide grounding as close to the unit as possible to shorten distance for grounding.

Handling precautions

Use the following UL-recognized DC power supply to combine with.

1. UL508-compatible limited voltage/current circuit

A circuit using the secondary coil of an insulating transformer that meets following conditions as power source.

Maximum voltage ( at no load ): 30Vrms ( 42.4Vpeak ) or below

Maximum current:( 1 ) 8A or less ( including when short-circuited )

( 2 ) When limited by the circuit protector ( such as fuse ) having the following rating.

No-Load Voltage ( Vpeak )

Max. Current Rating ( A )

0 to 20 [V]

5.0

 

 

Above 20 [V] to 30 [V]

100/peak voltage

 

 

2.UL1310-compatible Class 2 power supply unit or circuit of max. 30Vrms ( 42.4Vpeak ) or less using a UL1585-compatible Class 2 transformer as power source. ( Class 2 circuit )

2

3

Image 3
Contents Reduced wiring system Contents Otherwise injury can result Do not operate beyond specification rangeOtherwise injury or failure can result Otherwise accident caused by malfunction can resultSafety System configuration generalProduct Summary Part Names Dimensions unit mmMounting/Installation SI Unit Model Indication MethodPosition of End Plate Mounting/InstallationLayout of the EX9 series Output Block / Power Block Layout of the Input BlockMapping SpecificationsBasic specifications Higher-level busCable connection WiringCommunication wiring Power supply wiringSettings for display Display/SettingWiring Connecting one or two power supplies to SI UnitDisplay/Setting Switch settingDefault settings Block type EX250-IE1 EX250-IE2 EX250-IE3 Tie-rod 2 pcs AccessoryInput Block Model Indication Method Input Block Model indication methodEX250-IE1/2/3 Input wiring Cable wiringInput connector pin layout EX250-IE1 M12 connector, 5 pin, SocketEX250-IE1 EX250-IE2/IE3 Power BlockDisplay Output BlockPart Names Dimensions unit mm Output Block Power BlockTie-rod 2 pcs Waterproof cap Accessory For socket1 pc Pin alignment and connection drawing of the Output Cable SpecificationOutput wiring Cable wiring Output connector pin layoutPower supply wiring Power Block Power Cable Power BlockEX9-PE1 pin layout Option DisplayTroubleshooting OptionOverall system Green flashing Check the data rate and address TroubleshootingCheck the wiring and pin number EtherNet/IP compatible communication

EX250-SEN1 specifications

Sierra Monitor Corporation's EX250-SEN1 is a next-generation environmental monitoring solution designed to enhance the safety and efficiency of industrial operations. This advanced device excels in its core functionality, providing real-time monitoring and management of gas emissions and other environmental factors.

One of the main features of the EX250-SEN1 is its ability to detect a wide range of hazardous gases, including combustible gases, toxic gases, and oxygen levels. This capability is crucial in industries such as oil and gas, manufacturing, and wastewater treatment, where gas leaks can pose serious safety risks. The device ensures compliance with safety regulations by providing operators with timely alerts and notifications of any hazardous conditions.

The EX250-SEN1 utilizes advanced sensor technology that offers high precision and reliability. Its sensors are capable of rapid response times, allowing for quick detection and intervention in case of gas leaks. Moreover, the sensors have a long lifespan and minimal drift, which reduces the need for frequent recalibration, thereby lowering maintenance costs and downtime.

Another significant technology feature of the EX250-SEN1 is its integrated communication capabilities. It can seamlessly connect with existing industrial control systems and networks, including Modbus, Ethernet, and wireless communication protocols. This connectivity allows for real-time data sharing and integration into broader monitoring systems, enabling operators to analyze trends and make informed decisions.

The EX250-SEN1's user-friendly interface further enhances its usability. It includes a clear display that provides immediate access to key performance indicators and gas concentration levels. Operators can easily navigate through various settings and configurations, making adjustments as needed without extensive training.

Additionally, the device is designed with ruggedness and durability in mind. Built to withstand harsh industrial environments, the EX250-SEN1 is resistant to dust, moisture, and extreme temperatures. This resilience ensures reliable performance in the field, reducing the risk of false readings due to environmental factors.

In summary, the Sierra Monitor Corporation EX250-SEN1 is a cutting-edge environmental monitoring device that combines advanced sensor technology, robust communication capabilities, and user-friendly design. Its comprehensive features make it an ideal solution for industries that require vigilant monitoring of environmental safety, promoting a culture of safety and compliance.