Sierra Monitor Corporation PF2A7H instruction manual Specification

Page 12

Specification

Model

PF2A703H

 

PF2A706H

 

PF2A712H

Flow Rate Indication/Ran g e

 

 

Dry air

 

Flow rate indication range

125 to 3025

 

250 to 6050

 

550 to 12050

( /min)

 

 

 

 

 

 

 

Set flow rate range

125 to 3025

 

250 to 6050

 

550 to 12050

( /min)

 

 

 

 

 

 

 

Measured flow rate range

150 to 3000

 

300 to 6000

 

600 to 12000

( /min)

 

 

 

 

 

 

 

Measured min unit

5

 

10

 

( /min)

 

 

 

 

 

 

 

Flow rate converted

 

 

100 /pulse

 

score of integrated pulse

 

 

 

 

 

 

 

 

Integrated flow rate range

0 to 9,999,999,999

 

Indication Unit (*1,2)

Instantaneous flow rate : /min, CFM

 

Integrated flow rate :

, m3, m3×103, ft3, ft3×103, ft3×106

Operating fluid temp.

0 to 50(No condensation or freezing)

Linearliy

Indicated value

±1.5%F.S. or less

 

Analog output

 

±3%F.S. or less

 

 

 

 

Power supply voltage

24VDC, ripple±10% or less

Current consumption

150mA or less (No load)

Repeatability

±1.5%F.S. or less0.7MPa, 20

Hysteresis

Hysteresis mode : Variable (Settable starting 0)

Window comparator mode : Set for 0 to 3%F.S.

 

 

Response time

 

 

1s or less

 

Detecting method

 

Thermal sensing

 

Withstanding pressure

 

 

2.25MPa

 

Operation indication range

 

0.1 to 1.5MPa

 

Indication digit

5digits 7segment LCD

 

 

 

 

 

 

 

*1) With a unit selection function ( Without a unit selection function, fixed to SI unit [ /min or , m3, m3×103 ])

*2) Flow rate indication is possible to be switched to normal condition of 0/101.3kPa and standard condition of 20/101.3kPa/65%RH(ANR)

Model

PF2A703H

PF2A706H

 

PF2A712H

 

 

[NPN open collector] Max. load current : 80mA,

 

 

Internal voltage drop : 1V or less (At load current

(*3)

Switch output

80mA), Max. input voltage : 30VA

 

 

 

 

 

[PNP open collector] Max. load current : 80mA,

 

specification

 

 

Internal voltage drop : 1.5V or less

 

 

 

(At load current 80mA)

Integration pulse output

NPN/PNP open collector (Same as switch outputs)

 

Voltage output : 1 to 5V (within rated flow range)

Output

 

Linearliy : ±3%F.S. or less

 

Analog output

Permissible load impedance : 100kΩ or more

 

 

 

 

Current output : 4 to 20mA (within rated flow range)

 

 

 

 

Linearliy : ±3%F.S. or less

 

 

 

Permissible load impedance : 250Ω or more

Enclosure

 

IP65

 

Ambient temperature

Operation : 0 to 50, Storage : -25 to 85

range

(No condensation or freezing)

 

Withstand voltage

1000VAC, 1minute (between lead block and case)

Insulation resistance

50MΩ or less (at 500VDC M)

(between lead block and case)

 

 

Noise resistance

1000Vp-p pulse width 1μs first transition 1ns

Vibration proof

10 to 500Hz smaller one 1.5mm or 98m/s2, double

amplitude, each in directions of X,Y and Z 2hours

 

 

Impact proof

490m/s2, 3 tomes each in directions of X,Y and Z

Temp. characteristics

±2.0%F.S. or less (0 to 50, 25standard)

 

 

Attachment : A6063, Packin : H-NBR, Spacer : PPS,

Material

Mesh : SUS, Inner body : A6063, Sensor case : PPS,

 

 

Sensor : Leaded glass/ptlr/FeNi/OFC

 

Port size

1

11/2

 

2

Mass (Weight) (*4)

1.1kg

1.3kg

 

2.0kg

 

 

 

 

 

 

*3) Switch output and integrated pulse are selected at initial setting.

*4) Except lead wire.

20

21

Image 12 Contents
Digital Flow Switch Large Flow Rate Type Contents Do not operate beyond specification range Fire, malfunction or switch damage can result・Wiring correctly ・Do not wiring while power is on Do not use with a combustible fluidModel Indication Method Names and Functions of Individual PartsInstallation MountingPiping connections Example of Internal Circuit and Wiring Output Specification-28, -29 -68, -69Setting OUT1 Output SpecificationsInstantaneous switch output oU10 Function Setting Integration switch output oU11Key lock setting Display selecting mode Display unit selecting modeOutput specification selecting mode Output method selecting modeFlow rate setting mode Flow conversion modeInstantaneous switch output oU10 Error Display and Troubleshooting Other FunctionsFlow display check Clear of Integrated ValueSpecification Full View with Dimensions in mm Thred G