MURAL® LIGHTING CONTROLS •
Commercial Grade Lighting Controls
Mural L/S (Level Set) Decora-Style Preset Digital Dimmer
All Mural L/S dimmers provide
Mural L/S Preset Digital Dimmer 120V AC 60Hz Only U R
DESCRIPTION | CAT. NO. | RATING | COLOR* |
Mural L/S Incandescent LED Locator and | 600W | I, W, A | |
Brightness Display |
|
| (G, E, B with Kit) |
Mural L/S Incandescent LED Locator and | 1000W | I, W, A | |
Brightness Display |
|
| (G, E, B with Kit) |
Mural L/S Magnetic | 600VA (450W) | I, W, A | |
LED locator and Brightness Display |
|
| (G, E, B with Kit) |
Mural L/S Magnetic |
| 1000VA (800W) | I, W, A |
LED locator and Brightness Display |
|
| (G, E, B with Kit) |
Mural L/S Electronic |
| 350VA (280W) | W |
Locator and Brightness Display |
|
| (I, A, G, E, B with Kit) |
Mural L/S Advance Mark 10™ Powerline |
| 600VA | I, W, A |
Fluorescent Dimming Ballast |
|
| (G, E, B with Kit) |
LED Locator and Brightness Display |
|
|
|
Mural L/S Quiet Fan Speed Control | 1.5A | I, W, A | |
LED Locator and Brightness Display |
|
| (G, E, B with Kit) |
Mural L/S Incandescent LED Locator | 600W | I, W, A | |
(no brightness display) |
|
| (G, E with Kit) |
Mural L/S Incandescent LED Locator | 1000W | I, W, A | |
(no brightness display) |
|
| (G, E with Kit) |
Mural L/S Magnetic | 1000VA (800W) | I, W, A | |
LED Locator (no brightness display) |
|
| (G, E with Kit) |
| No load rating | I, W, A | |
|
| (G, E, B with Kit) | |
(no LED locator or display) |
|
|
|
| No load rating | W | |
|
| (I, A, G, E, B with Kit) | |
(no LED locator or display) |
|
|
|
Color Change Kits for Mural L/S |
| — | I, W, A, G, E, B |
(ML versions) |
|
|
|
Color Change Kits for | — | I, W, A, G, E, B | |
(no LED locator or display) |
|
|
|
Color Change Kit for Mural L/S (MR versions) |
| — | I, W, A, G, E |
See Page C8 for more information on Leviton Power Extenders
Note: Sharing a neutral wire may cause flickering. Connect all dimmers to the same phase or run a separate neutral to each phase. Consult Leviton Techline if problems persist.
Digital Lighting and Fan Speed Controls are polarity sensitive devices. Always follow the wiring instructions included with each device. They can be used in conventional
4.13 (104.9) | 3.28 (83.3) | 2.67 (67.9) |
2.38 (60.5) | 1.38 |
| (35.1) |
4.13 (104.9) | 3.28 (83.3) | 2.67 (67.9) |
2.38 (60.5) | 1.38 |
| (35.1) |
Lighting Controls
CAUTION ON RETROFITS: When retrofitting Mark 10™ Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start sockets to allow proper dimmer operation and prevent dam- age to the dimming ballast. Refer to the instructions provided with the ballast and the Leviton Mark 10™ dimmer.
SPECIFICATIONS AND FEATURES
•Smooth Decora
•Arrow rocker allows user to set brightness level when lights are off
•Second tap on top half of rocker for full bright. Gently double tap bottom half of rocker for fast OFF
•Easy to operate for people of all ages and abilities
•Provides
•Streamlined, popular Decora styling enhances any interior and adds a “family look” when ganged with any Decora device
•Digital circuitry provides
•Square green LED display alongside rocker indicates selected brightness level on ML models
•Locator LED illuminates when lights are OFF
•Color change kits available in a wide range of choices, making it easy and economical to change decorating schemes
•Color change kits simplify inventory for distributors and contractors who can offer a complete range of colors without stocking a different device for each one
•Minimum brightness adjustment sets comfortable minimum light level
•Power failure recovery assures retention of lighting levels during
•
•ON/OFF AC
TESTING AND CODE COMPLIANCE
•UL Listed (File
•CSA Certified (File
•Backed by a Limited
*COLOR
To order colors, add suffix to basic catalog number. Colors in parentheses must be ordered as Color Change Kits. Color suffixes are: Ivory
MATERIAL CHARACTERISTICS
Environmental: Flammability
Operating Temperature: 32°F to 130°F
Use Leviton Power Extenders to extend the load capacity of
C
For answers to technical questions, call Leviton’s Techline at
Courtesy of Steven Engineering,