Xantech HD44C IR Receiver, Plug Circuit, IR BUS, Emitter Port, RS232 Serial Commands, Circuit PIN

Page 3

[3] IR RECEIVER

The rear panel IR receiver is a 3.5mm Stereo jack that is compatible with all Xantech IR receivers, such as the 291-10. Switch 4 must be in the OFF position to use this jack.

PLUG

CIRCUIT

TIP

IR SIGNAL

RING

GROUND

SLEEVE

+12VDC, 25mA

[4] IR BUS, EMITTER PORT

The 3.5mm Mono jack is an emitter port. The IR signal is connected to the IR Receiver. A Xantech 283M emitter can be connected to this port.

PLUG

CIRCUIT

TIP

IR SIGNAL

SLEEVE

GROUND

The 2-Pin WECO screw terminal is an IR port. The IR signal is connected to the IR Receiver. The WECO screw terminal allows easy installation to a typical Xantech IR connecting block.

[5] RS232 (SERIAL) COMMANDS

The RS232 Port is bi-directional. The communication is set to 9600 Baud 8-N-1.

DB9 CONNECTOR

CIRCUIT PIN

TX 2

RX 3

GND 5

RS232 COMMAND STRUCTURE

Where:

{z#} - Zone Number. Range is 1..4 (1..16 if expanded) {s#} - Source Input Number. Range is 1..4

{0/1} – Either 0 (zero) or 1 (one). 0 – Off, 1 – On.

 

NAME

 

 

COMMAND

 

 

REMARKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone Power

 

!{z#}PR{0/1}+

To turn on Zone 2: !2PR1+

 

 

 

 

 

 

 

To turn off Zone 1: !1PR0+

Zone Power Toggle

 

!{z#}PT+

 

 

 

All Zones Off

!AO+

 

 

 

Zone Restore All

!RF+

 

Restore all the Zone-to-Source routing: !RF+

Input (Source) Select

 

!{z#}SS{s#}+

To set Zone 1 to Source Input 5: !1SS5+

 

 

08905071A

- 3 -

Image 3
Contents Description SpecificationsSource Inputs Detail Overview Source LOOP-THROUGH ConnectionPlug Circuit RS232 Serial CommandsRS232 Command Structure IR ReceiverRS232 Expansion AC Power InputAddress DIP Switch RS232 QueriesCoaxial Zone Output CAT5 Zone OutputQuick Installation HD44CC5 and HDRXSG01 RC68+ IR Commands Advance Installation 08905071A Page Page 08905071A