RS232 QUERIES

NAME

QUERY

RESPONSE

EXAMPLE

 

 

 

 

Zone Power

?{z#}PR+

?{z#}PR{0/1}+

?7PR0+

Input Select

?{z#}SS+

?{z#}SS{s#}+

?5SS3+

EXPLANATION

Power in zone 7 is OFF. Zone 5 is Source 3.

[6] AC POWER INPUT

Standard IEC 3-Conductor AC Line Cord Receptacle for plug-in of a 3-conducator power line cord. Be sure to note if the power receptacle is domestic (120VAC type) or international (240VAC type).

[7] RS232 EXPANSION

The HD44C and HD44CC5 can be expanded into a larger system. By using any combination of the HD44C and HD44CC5 (up to 8 systems), a larger High-Definition distribution system can be created.

For instance, two HD44C systems can be combined to create a much larger 4 source input to 8 zone output. The two HD44C systems must have its own unique address (see ADDRESS (DIP SWITCH) section). The included RS232 expansion cable allows a single RS232 control port to be used to command the entire system. The expansion cable is connected between the DB9 (5) and 3.5mm stereo mini jack (7).

DB9 MALE

CIRCUIT

PIN

TX

2

RX

3

GND

5

3.5MM PLUG

PLUG

CIRCUIT

TIP

TX

RING

RX

SLEEVE

GND

[8] ADDRESS (DIP SWITCH)

Switch 1 & 2: Unit Address (for Expansion mode)

ADDR

SW 1

SW 2

UNIT 1

ON

ON

UNIT 2

ON

OFF

UNIT 3

OFF

ON

UNIT 4

OFF

OFF

Switch 3: ON for firmware write protect

Switch 4: ON for front panel IR receiver / OFF for rear panel IR receiver

 

 

08905071A

- 4 -

Image 4
Contents Specifications DescriptionDetail Overview Source LOOP-THROUGH Connection Source InputsRS232 Serial Commands RS232 Command StructureIR Receiver Plug CircuitAC Power Input Address DIP SwitchRS232 Queries RS232 ExpansionCAT5 Zone Output Coaxial Zone OutputQuick Installation HD44CC5 and HDRXSG01 RC68+ IR Commands Advance Installation 08905071A Page Page 08905071A