Xantech DCH4 installation instructions Security Code, DIP Switch Programming, Privacy Number

Page 5

C. Security Code

This six digit number can be used to access the programming mode. The security code has been factory set to 845464. It is recommended that you change the security code to a personal 6 digit number. To change the security code, access programming (see Programming section A). Enter six digits 0-9 followed by #47. If you have forgotten your security code, follow the steps in Programming section A, 2. Accessing the Programming Mode Locally (Security Code Bypass Mode). Note: The security code must be six digits in length and can NOT contain a * or #.

D. DIP Switch Programming

 

SWITCH

 

 

POSITION

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

OFF

 

Auxiliary Contact Mode.

 

 

 

 

 

 

1

 

 

ON

 

Doorbell Mode (Factory setting).

 

 

 

 

 

 

2

 

 

OFF

 

Normal Operation Mode (Factory setting).

 

 

 

 

 

2

 

 

ON

Security Code Bypass Mode.

 

 

 

 

 

3

 

 

OFF

Entry Phone automatic disconnect (CPC) disabled.

 

 

 

 

 

 

 

3

 

 

ON

Entry Phone automatic disconnect (CPC) enabled

 

 

(Factory setting).

 

 

 

 

 

 

4

 

 

OFF

Entry Phone busy signal disabled.

 

 

 

 

 

4

 

 

ON

Entry Phone busy signal enabled (Factory setting).

 

 

 

 

 

 

 

 

 

E. Privacy Number

The “Privacy Number” is factory disabled so an entry phone off-hook will automatically ring the house phones. If a “Privacy Number” is programmed, the visitor must Touch Tone dial the number to be able to call into the house. The “Privacy Number” may be from 1 to 6 digits and is stored in location “#00”.

To disable the “Privacy Number,” clear the number’s memory location by entering “#00” without any previous digits.

F. Keyless Entry Codes and One Time Use Keyless Entry Codes

Each entry phone may have a combination of up to 6 keyless entry codes or one time use keyless entry codes for Touch Tone keyless entry. The keyless entry codes may be from 4 to 6 digits in length and are stored in locations #11 - #16 for entry phone 1, #21 - #26 for entry phone 2, #31 - #36 for entry phone 3, and #41 - #46 for entry phone 4. Up to 6 master keyless entry codes may be from 4 to 6 digits in length and are stored in locations #51 - #56. The master keyless entry codes can be used at any entry phone. To change any of the keyless entry codes to one time use, insert a * in front of the specific memory location during programming (ie: “*#11”). To clear any keyless entry codes, simply enter the location number (ie: “#11” or “*#11”) without any previous digits.

 

 

08905107C

- 5 -

Image 5
Contents Description SpecificationsDoor Strike, Relay Contact Output. N.O., COM, N.O Entry Phone InputAuxiliary Relay Contact Output. N.C., COM, N.O ApplicationProgramming Accessing the Programming Mode Remotely StepLine OUT to Phones OUT to PhonesQuick Programming Features Security Code DIP Switch ProgrammingPrivacy Number Keyless Entry Codes and One Time Use Keyless Entry CodesDoorbell Switch Input and Auxiliary Contact Output Outside Line AccessDoor Strike Activation Time Caller IDEntry Phone Triggered Continuous Activation Auxiliary Contact Mode DIP Switch 1 OFFEntry Phone Triggered Ring Cadence Activation Auxiliary Input Triggered Timed ActivationVisitors OperationEntry Phone Caller ID and Call Waiting ID Monitoring Activating Doorstrike/GateOperation Commands Touch Tone Commands Xantech CORPORATION, 13100 Telfair AVE. SYLMAR, CA 91342 818