3.9.2Humidity
3.9.2.1Relative humidity
Operating: | 5% to 90% noncondensing (30% per hour max) |
|
|
Nonoperating: | 5% to 95% noncondensing (30% per hour max) |
|
|
3.9.3Altitude
Operating: | |
|
|
Nonoperating: | |
|
|
3.9.4Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. Shock may be applied in the X, Y or Z axis.
3.9.4.1Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum operating shock of 70 Gs (read) and 40 Gs (write) based on
3.9.4.2Nonoperating shock
1TB and 500GB models
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 350 Gs based on a nonrepetitive
2TB models
The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 300 Gs based on a nonrepetitive
18 | Constellation ES Serial ATA Product Manual, Rev. G |